Switching Specifications
For 0°C TA 70°C, 4.5 V VCC 20 V, VE = 0.8 V, all typicals at TA = 25°C and VCC = 5 V unless
otherwise noted. See note 13.
Parameter
Symbol Min. Typ. Max. Units Test Conditions Fig. Note
Propagation Delay Time
tPLH
0.23 1.6 µs VE = 0 V,
8, 9, 7
to Logic High Output Level
CL = 15 pF
10
Propagation Delay Time
tPHL
to Logic Low Output Level
0.17 1.0 µs VE = 0 V,
CL = 15 pF
8, 9, 8
10
Propagation Delay Time
tPLH - tPHL
60
ns II = 20 mA,
8, 9,
Skew
CL = 15 pF
10
Output Enable Time to
tPZL
25
ns II = 0 mA,
12, 13,
Logic Low Level
CL = 15 pF
15
Output Enable Time to
tPZH
Logic High Level
28
ns II = 20 mA,
12, 13,
CL = 15 pF
14
Output Disable Time to
tPLZ
60
ns II = 0 mA,
12, 13,
Logic Low Level
CL = 15 pF
15
Output Disable Time to
tPHZ
105
ns II = 20 mA,
12, 13,
Logic High Level
CL = 15 pF
14
Output Rise Time
(10-90%)
tr
55
ns VCC = 5 V,
8, 9, 9
CL = 15 pF
11
Output Fall Time
tf
15
ns VCC = 5 V,
8, 9, 1 0
(90-10%)
CL = 15 pF
11
Common Mode Transient
|CMH| 1,000 10,000
V/µs VCM = 50 V (peak) 1 6 1 1
Immunity at Logic High
II = 12 mA,
Output Level
TA = 25°C
Common Mode Transient
Immunity at Logic Low
Output Level
|CML| 1,000 10,000
V/µs VCM = 50 V (peak) 1 6 1 2
II = 3 mA,
TA = 25°C
Package Characteristics
For 0°C TA 70°C, unless otherwise specified. All typicals at TA = 25°C.
Parameter
Symbol Min. Typ. Max. Units Test Conditions Fig.
Input-Output Momentary VISO
Withstand Voltage*
Resistance, Input-Output RI-O
Capacitance, Input-Output CI-O
2500
1012
1.0
V rms
ohms
pF
RH 50%, t = 1 min,
TA = 25°C
VI-O = 500 V dc
f = 1 MHz, VI-O = 0 V
Notes
6, 14
6
6
*The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output
continuous voltage rating. For the continuous voltage rating refer to the VDE 0884 Insulation Characteristics Table (if applicable),
your equipment level safety specification, or HP Application Note 1074, “Optocoupler Input-Output Endurance Voltage.”
1-328