DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MM1293 查看數據表(PDF) - Mitsumi

零件编号
产品描述 (功能)
生产厂家
MM1293 Datasheet PDF : 6 Pages
1 2 3 4 5 6
MITSUMI
Protection of Lithium Ion Batteries (three cells in series) MM1293
Pin Assignment
Pin no.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Pin name
OV
CS
DCHG
PF
CDC
COL
COV
MSW
GND
Input/output
Function
Output
Input
Output
Output
Input
Input
Input
Input
Overcharge detection output pin
NPN transistor open collector output; normally high impedance, goes to L
level on overdischarge
Overcurrent detection pin
Monitors equivalent load current through source-drain voltage drop of discharge-controlling
FET, and at or above the overcurrent detection voltage sets the DCHG pin to "H" and turns
off the discharge-controlling FET. Following overcurrent detection, current is passed from
this pin, and if the load is decreased, the overcurrent mode is canceled. Through this action
there is a temporary consumption current (at the VCC pin) of approx. 1 mA on resumption of
discharge and detection of overdischarge. This function is disabled in overdischarge mode.
Pin driving the discharge-controlling FET (P-ch)
Normally "L"; on overdischarge set to "H"
Output pin for overdischarge detection signals
Overdischarge detection pin
When the overdischarge detector detects overdischarge at the open collector output of
the NPN transistor, this pin is turned on. A delay is provided by setting a dead time until
discharge ends, so that by utilizing a reset or other signal from a CPU or some other
controlling device, the equipment can be put into standby mode.
Pin to set the dead time for overdischarge detection
By connecting a capacitor between the CDC pin and GND, a dead time can be set.
Pin to set the dead time for overcurrent detection
Pin to set the dead time for overcurrent detection
By connecting a capacitor between the COL pin and GND, a dead time can be
set. If NC, protection is triggered in a short amount of time; the dead time
should be set according to the application.
Pin to set the dead time for overcharge detection
By connecting a capacitor between the COV pin and GND, a dead time can be
set.
Pin to switch the cell voltage monitor on/off
GND: monitor on, VCC: monitor off
The cell voltage monitor converts the different cell voltages to a GND-
reference voltage and outputs it from the ML, MM and MH pins.
Input Ground pin
ML
Output Monitor output pin for the L cell voltage
BATL
Input Pin for input of L cell high-side voltage and M cell low-side voltage
MM
Output Monitor output pin for the M cell voltage
BATM
Input Pin for input of M cell high-side voltage and H cell low-side voltage
MH
Output Monitor output pin for the H cell voltage
BATH
Input Pin for input of H cell high-side voltage
VCC
Input
Power supply input pin
The same potential as the BATH pin should be input
Absolute Maximun Ratings (Ta=25°C)
Item
Storage temperature
Operating temperature
Charge voltage
Power supply voltage
Voltage applied to OV pin
Allowable loss
Symbol
TSTG
TOPR
VBAT max.
VCC max.
VOV max.
Pd
Ratings
-40~+125
-20~+70
18
18
18
300
Units
°C
°C
V
V
V
mW