MC33293A
Figure 3. Fault Status Operation with an Output-On, Open-Load Fault
5.0V
Vin
3.0V
1.0V
0V
5.0V
VStatus
0V
IO
0A
1.0V
tos(on) *
Open Load
Fault Reported
* If the open occurs after the output has been on,
the delay time is much less than tos(on).
NOTE: Rise and fall times are exaggerated for emphasis.
Open Load
Fault Ends
1.0A
(Normal Load)
IOon(th)
Figure 4. Fault Status Operation with an Output-Off, Open-Load Fault
5.0V
Vin
2.5V
0V
5.0V
VStatus
(All Outputs Off)
0V
VO
0V
1.0V
tos(off) *
Open Load
Fault Reported
* If the open occurs after the output has been off, the
delay time is much less than tos(off).
NOTE: Rise and fall times are exaggerated for emphasis.
ts(reset)
Open Load
Fault Ends
3.0V
VOoff(th)
Vload
MOTOROLA ANALOG IC DEVICE DATA
7