IS61SP12832
IS61SP12836
OPERATING RANGE
Range
Commercial
Industrial
Ambient Temperature
0°C to +70°C
–40°C to +85°C
VCC
3.3V, +10%, –5%
3.3V, +10%, –5%
ISSI ®
DC ELECTRICAL CHARACTERISTICS(1) (Over Operating Range)
Symbol
VOH
VOL
VIH
VIL
ILI
Parameter
Output HIGH Voltage
Output LOW Voltage
Input HIGH Voltage
Input LOW Voltage
Input Leakage Current
ILO
Output Leakage Current
Test Conditions
IOH = –4.0 mA
IOL = 8.0 mA
GND ≤ VIN ≤ VCCQ(2)
GND ≤ VOUT ≤ VCCQ, OE = VIH
Com.
Ind.
Com.
Ind.
Min.
2.4
—
2.0
–0.3
–2
–5
–2
–5
Max.
—
0.4
VCCQ + 0.3
0.8
2
5
2
5
Unit
V
V
V
V
µA
µA
POWER SUPPLY CHARACTERISTICS (Over Operating Range)
-200
-166
-150
-133
-5
Symbol Parameter
Test Conditions
Max.
Max.
Max.
Max
Max.
Unit
ICC
AC Operating
Device Selected,
Com.
310
290
270
230
210
mA
Supply Current All Inputs = VIL or VIH
Ind.
—
300
280
240
220
mA
OE = VIH, Vcc = Max.
Cycle Time ≥ tKC min.
ISB
Standby Current Device Deselected,
Com.
70
70
70
70
65
mA
VCC = Max.,
Ind.
—
80
80
80
75
mA
All Inputs = VIH or VIL
CLK Cycle Time ≥ tKC min.
IZZ
Power-downMode ZZ = VCC
Com.
15
15
15
15
15
mA
Current
Clock Running
Ind.
20
20
20
20
20
mA
All Inputs ≤ GND + 0.2V
or ≥ Vcc – 0.2V
Notes:
1. The MODE pin has an internal pullup. This pin may be a No Connect, tied to GND, or tied to VCC.
2. The MODE pin should be tied to Vcc or GND. It exhibits ±10 µA maximum leakage current when tied to ≤ GND + 0.2V
or ≥ Vcc – 0.2V.
Integrated Silicon Solution, Inc. — 1-800-379-4774
7
PRELIMINARY INFORMATION Rev. 00B
04/04/00