SMART 3 ADVANCED BOOT BLOCK
E
4.2 Operating Conditions
Symbol
Parameter
Notes
Min
Max
Units
TA
VCC1
VCC2
VCC3
VCCQ1
VCCQ2
VCCQ3
VPP1
Operating Temperature
VCC Supply Voltage
I/O Supply Voltage
Program and Erase Voltage
–40
+85
°C
1
2.7
3.6
Volts
2.7
2.85
2.7
3.3
1
2.7
3.6
Volts
1.65
2.5
1.8
2.5
1
2.7
3.6
Volts
VPP2
2.7
2.85
VPP3
2.7
3.3
VPP4
2, 3
11.4
12.6
Cycling
Block Erase Cycling
3
100,000
Cycles
NOTES:
1. VCC1, VCCQ1, and VPP3 must share the same supply when all three are between 2.7 V and 3.6 V.
2. During read operations or idle time, 5 V may be applied to VPP indefinitely. VPP must be at valid levels for program and
erase operations
3. Applying VPP = 11.4 V–12.6 V during a program/erase can only be done for a maximum of 1000 cycles on the main blocks
and 2500 cycles on the parameter blocks. VPP may be connected to 12 V for a total of 80 hours maximum. See Section 3.4
for details.
4.3 Capacitance
TA = 25 °C, f = 1 MHz
Sym
Parameter
CIN Input Capacitance
COUT Output Capacitance
NOTE:
1. Sampled, not 100% tested.
Notes Typ
1
6
1
10
Max
8
12
Units
pF
pF
Conditions
VIN = 0 V
VOUT = 0 V
24
PRELIMINARY