DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

CMX860 查看數據表(PDF) - MX-COM Inc

零件编号
产品描述 (功能)
生产厂家
CMX860 Datasheet PDF : 36 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
Telephone Signaling Transceiver
16
CMX860 Advance Information
4.12.1 General Reset Command (no data) ($01)
This command resets the device and clears all bits of the General Control, Transmit Mode and Receive Mode
Registers and bits 15 and 13-0 of the Status Register.
Whenever power is applied to the CMX860 a General Reset command should be sent to the device, after
which the General Control Register should be set as required.
a) Single byte from µC
CS
SERIAL CLOCK
COMMAND DATA
765432 10
REPLY DATA
Address (01 Hex = Reset)
Hi-Z
b) One Address and one Data byte from µC
CS
SERIAL CLOCK
COMMAND DATA
765432 10
Address
REPLY DATA
Hi-Z
Note:
The SERIAL CLOCK line may be high
or low at the start and end of each
transaction.
= Level not important
765432 10
Data to CMX860
c) One Address and 2 Data bytes from µC
CS
SERIAL CLOCK
COMMAND DATA
765432 10
Address
REPLY DATA
Hi-Z
765432 10
First (msb) data
byte to CMX860
765432 10
Second (lsb) data
byte to CMX860
d) One Address byte from µC and one Reply byte from CMX860
CS
SERIAL CLOCK
COMMAND DATA
765432 10
Address
REPLY DATA
Hi-Z
765432 10
Data from CMX860
e) One Address byte from µC and 2 Reply bytes from CMX860
CS
SERIAL CLOCK
COMMAND DATA
765432 10
Address
REPLY DATA
Hi-Z
765432 10
First (msb) byte
from CMX860
765432 10
Second(lsb) byte
from CMX860
Figure 13: C-BUS Transactions
¤2000 MX-COM, Inc.
www.mxcom.com tel: 800 638 5577 336 744 5050 fax: 336 744 5054
Doc. # 20480222.001
4800 Bethania Station Road, Winston-Salem, NC 27105-1201 USA All trademarks and service marks are held by their respective companies.

Share Link: 