TN
10. Actual load test (35 mA 48 V DC wire spring relay load)
Tested sample: TN2-12V, 5 pcs.
Change of pick-up and drop-out voltage
Change of contact resistance
100
100
90
90
80
80
70
Pick-up voltage
70
Max.
60
Min.
60
50
50
40
40
Terminal No. 2–3
Drop-out voltage
30
Max.
30
20
Min.
20
10
10
0
10
20
30
40
50
No. of operations,×104
0
10
20
30
40
No. of operations, ×104
Max.
Min.
50
DIMENSIONS (mm inch)
The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e
CAD Data
External dimensions
Standard PC board terminal
14
5.6
551
.220
9.8 9.5
.386 .374
3.5
.138
2.54
0.5
.100
.020
0.25
1.385
.010
.055
2.54
.100
PC board pattern (Bottom view)
10.16
.400
2.54
.100
2.54
.100
10-1.0 dia. hole
10-.039 dia. hole
Tolerance: ±0.1 ±.004
Self-clinching terminal
14
551
5.6
.220
Schematic (Bottom view)
Single side stable
1-coil latching
2-coil latching
9.8 9.5
.386 .374
12345
12345
12345
3.5
.138
0.25
10 9 8 7 6
10 9 8 7 6
2.54
0.5
.100
.020
1.385
.055
.010 2.54
.100
Direction indication
Direction indication
(Deenergized condition)
(Reset condition)
General tolerance: ±0.3 ±.012
10 9 8 7 6
Direction indication
(Reset condition)
NOTES
1. Packing style
The relay is packed in a tube with the
relay orientation mark on the left side, as
shown in the figure bel w.
Orientation (indicates PIN No.1) stripe
Stopper
(gray)
Stopper
(green)
2. Automatic insertion
To maintain the internal function of the
relay, the chucking pressure should not
exceed the values below.
Chucking pressure in the direction A:
9.8 N {1 kgf} or less
Chucking pressure in the direction B:
9.8 N {1 kgf} or less
Chucking pressure in the direction C:
4.9 N {500gf} or less
C
B
A
For general cautions for use,
please refer to the “Cautions for
use of Signal Relays” or “General
Application Guidelines”.
Please chuck the portion.
Avoid chucking the center of the relay.
In addition, excessive chucking pressure
to the pinpoint of the relay should be
avoided.
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e