DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

DS1743P-100IND 查看數據表(PDF) - Maxim Integrated

零件编号
产品描述 (功能)
生产厂家
DS1743P-100IND
MaximIC
Maxim Integrated MaximIC
DS1743P-100IND Datasheet PDF : 17 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
DS1743/DS1743P Y2K-Compliant, Nonvolatile Timekeeping RAMs
The pre-existing contents of the Control register bits 0:5 (Century value) will not be modified by a write
cycle to Control if the R bit is being cleared to 0 in that write operation.
STOPPING AND STARTING THE CLOCK OSCILLATOR
The clock oscillator may be stopped at any time. To increase the shelf life, the oscillator can be turned off
to minimize current drain from the battery. The OSC bit is the MSB (bit 7) of the seconds registers, see
Table 2. Setting it to a 1 stops the oscillator.
FREQUENCY TEST BIT
As shown in Table 2, bit 6 of the day byte is the frequency test bit. When the frequency test bit is set to
logic 1 and the oscillator is running, the LSB of the seconds register will toggle at 512Hz. When the
seconds register is being read, the DQ0 line will toggle at the 512Hz frequency as long as conditions for
access remain valid (i.e., CE low, OE low, WE high, and address for seconds register remain valid and
stable).
CLOCK ACCURACY (DIP MODULE)
The DS1743 is guaranteed to keep time accuracy to within ±1 minute per month at +25°C. The RTC is
calibrated at the factory by Dallas Semiconductor using nonvolatile tuning elements, and does not require
additional calibration. For this reason, methods of field clock calibration are not available and not
necessary. The electrical environment also affects clock accuracy, so caution should be taken to place the
RTC in the lowest-level EMI section of the PC board layout. For additional information, please refer to
Application Note 58: Crystal Considerations with Dallas Real-Time Clocks.
CLOCK ACCURACY (PowerCap MODULE)
The DS1743 and DS9034PCX are each individually tested for accuracy. Once mounted together, the
module will typically keep time accuracy to within ±1.53 minutes per month (35ppm) at +25°C. The
electrical environment also affects clock accuracy, so caution should be taken to place the RTC in the
lowest-level EMI section of the PC board layout. For additional information, please refer to Application
Note 58: Crystal Considerations with Dallas Real-Time Clocks.
6 of 17