Board Mountable
DC-DC Converters
IML 10 Series
Table 6: Insulation concept leading to an SELV output circuit
Conditions Front end
DC-DC converter
Result
Supply
voltage
Minimum required grade Maximum
of isolation, to be provided DC output
by the AC-DC front end, voltage
including mains supplied from the
battery charger
front end 1
Minimum required safety
status of the front end
output circuit
Measures to achieve the
specified safety status of the
output circuit
Safety status of
the DC-DC
converter output
circuit
Mains
Basic
250 V AC
60 V
Earthed SELV circuit 2
Operational insulation, pro- SELV circuit
vided by the DC-DC converter
>60 V
ELV circuit
Hazardous voltage
secondary circuit
Input fuse 3 output suppressor
diode(s) 4, and earthed
output circuit(s) 2
Earthed SELV
circuit
Double or reinforced
60 V
SELV circuit
Operational insulation, pro- SELV circuit
vided by the DC-DC converter
>60 V
TNV-2 circuit
Double or reinforced insu-
lated unearthed hazardous
voltage secondary circuit 5
Supplementary insulation,
based on the maximum input
voltage, provided by the
DC-DC converter
1 The front end output voltage should match the specified input voltage range of the DC-DC converter.
2 The earth connection has to be provided by the installer according to the relevant safety standard, e.g. IEC/EN 60950.
3 The installer shall provide an approved fuse (type with the lowest rating suitable for the application) in the non-earthed input line di-
rectly at the input of the DC-DC converter (see fig.: Schematic safety concept). For ULs purpose, the fuse needs to be UL-listed. See
also: Input Fuse.
4 Each suppressor diode should be dimensioned in such a way, that in the case of an insulation fault the diode is able to limit the output
voltage to SELV (<60 V) until the input fuse blows (see fig.: Schematic safety concept).
5 Has to be insulated from earth by basic insulation according to the relevant safety standard, based on the maximum output voltage
from the front end.
~
Mains
~
AC-DC
front
end
Fuse
DC-DC
Battery con-
verter
10004
+
Suppressor
diode SELV
Earth
Earth
connection
connection
Fig. 6
Schematic safety concept. Use fuse, suppressor diode
and earth connection as per table: Safety concept leading
to an SELV output circuit.
Edition 6/4.2000
6/7