Electrical specifications
2.1 Electrical Connection
Connector: Molex, Picoflex PF-50, see picture 2.
Name
Function
Connector
pin #
Vcc
Power supply
1
NC
Internally not connected
2
GND
Ground
3
Out X Analogue X-direction output
4
Out Y Analogue Y-direction output
5
NC
Internally not connected
6
2.2 Absolute maximum ratings
Parameter
Condition
Supply voltage
Current consumption
Output load
(ratiometric output)
No load
Resistive
Storage temp
Capacitive
Operating temp
Mechanical shock
1m drop on concrete
2.3 Electrical Specification
Parameter
Condition
Supply voltage
Measuring range (1
Offset (2,3,4
Offset calibration point error (3,4,5
Offset temperature error (3,4,6
Output @ 0°
0°C…70°C
Sensitivity (3,4,7
Sensitivity calibration error (3,4,8
Sensitivity temperature error (3,4,9
-25°C…85°C
@ 0° (offset position)
0°C…70°C
Nonlinearity (10
Ratiometric error (11
-25°C…85°C
Sine fitting
Frequency response –3dB
True DC response
Output noise DC…10 Hz
@ 0° (offset position)
Min.
4.5
30
-40
-25
Typ
5.0
4
50
20 000
Max.
5.5
6
20
125
85
Units
V
mA
k
nF
°C
°C
g
Min.
4.75
198
Typ
5.0
± 10
2.5 ± 0.02
± 0.1
± 0.2
± 0.5
200
± 0.5
± 1.0
± 0.03
±2
3
< 0.001
Max.
5.25
202
1%
Units
V
°
V
°
°
°
mV/ °
%
%
%
°
%
Hz
°
Note 1.
Note 2.
Note 3.
Note 4.
Note 5.
Note 6.
Note 7.
Note 8.
The measuring range is limited by sensitivity, offset and supply voltage rails of the device.
Offset specified as Voffset = Vout(@0°) [V].
+5.0V supply voltage used in calibration and testing.
See proposed connection of SCL1700 in picture 2.
Offset calibration error specified as Offset_Calib_error = arcsin(Offset_Calib_error_in_g) [ ° ],
Offset_Calib_error_in_g = {Vout(@0°) – 2.5 V} / Vsens [g], Vsens=11.46 V/g.
Offset temperature error specified as Offset_Error_@_temp. = arcsin(Offset_Error_@_temp_in_g) [ ° ],
Offset_Error_@_temp_in_g = {Vout @ temp. – Vout @ room temp.} / Vsens [g], Vsens=11.46 V/g.
Sensitivity target in calibration 11.46 V/g (à 200 mV/°)
Sensitivity specified as Vsens = {Vout(@+10°) - Vout(@+10°)}/(2*sin(10°) g) [V/g].
Sensitivity calibration error specified as Sensitivity_calibr_error = {Vsens - Vsens_nom} / Vsens_nom x 100% [%],
Vsens_nom = nominal sensitivity.
VTI Technologies Oy