TP8452
PS/2 2D 3Key Mouse
Controller
d. Data Output ( data from TP8452 to system ):
If CLK keep low (inhibit status), data will not transmit.
If CLK raised to high and DATA is low(request-to-send),data is updated.
After receiving data from system, TP8452 will not start transmitting until CLK and DATA
are both high.
If CLK and DATA are both high, the transmission is ready.
DATA is valid prior to the falling edge of CLK and beyond the rising edge of CLK. During
transmission, TP8452 check for line contention by checking for an inactive level on CLK
lasting for no more than 100m sec.
Contention occurs when the system lowers CLK to inhibit TP8452 output after TP8452
has started a transmission. If this occurs before the rising edge of the tenth clock, TP8452
internal store its data in its buffer and returns DATA and CLK to an active level. If the
contention does not occur by the tenth clock, the transmission is completed.
Following a transmission, the system inhibits TP8452 by holding CLK low until it can
service the input or until the system receives a request to send a response from TP8452.
e. Data Input ( from system to TP8452):
System first check if TP8452 is transmitting data. If TP8452 is transmitting, the system
can override the output by forcing CLK to an inactive level prior to the tenth clock. If the
transmission of TP8452 beyond the tenth clock ,the system must receive the data.
If TP8452 is not transmitting or if the system choose to override the output, the system
force CLK to an inactive level for a period of not less than 100u sec while preparing for
output. When the system is ready to output start bit (0), it allows CLK to go to active level.
If request-to-send is detected, TP8452 clocks in 11 bits. Following the tenth clock,TP8452
checks for an active level on the DATA line, and if found, force DATA low , and clock once more.
If framing error occurs, TP8452 continue to clock until DATA is high, then clocks the line
control bit and request a Resend.
When the system sends out a command or a data that requires a response, the system must
wait for TP8452 to response before sending its next output.
(D) PS/2 Mouse Error Handling: