2.7.Lighting Specifications
Ta=25℃
Parameter
Symbol Conditions
Min.
Typ.
Max.
Units Notes
Lamp Voltage
VL
-
-
220
-
Vrms 1
Lamp Current
IL
-
4.0
5.0
6.0
mArms 2
Starting Voltage
VS
-
-
630
-
Vrms 3
Surface Luminance
L
IL=5.0mA
40
50
-
cd/㎡ 4
Average Life
TAL
IL=5.0mA
10000
15000
-
hrs
5
Note 1 : The voltage ( r.m.s. ) to maintain the electric discharge of the lamp. It is measured after lighting for
3 minutes .
Note 2 : The current ( r.m.s. ) to flow through the lamp with the electric discharge. It is measured after
lighting for 3 minutes.
Note 3 : The voltage at starting the electric discharge when the voltage is increased gradually from 0V.
Note 4 : Surface Luminance is specified by the initial data of luminance measured at the center of display
surface after 20 minutes power on. ( All ON pattern )
Note 5 : CFL life is defined as the time for which the initial luminance is attenuated by 50% of the
luminance value. Average Life representes the time elapsed at the point of time when the residual
ratio becomes below 50% when plural lamps are lighted in comparison with the definition of life
mentioned above.
I
N
VS
V
C
VL
F
L
IL
CFL Testing Circuit
Recommended Inverter : S-12561 ( Produced by ELEVAM ) CXA-L10L ( Produced by TDK)
DMF-50174ZNB-FW (AT) No.2000-0166
OPTREX CORPORATION
OPTREX
Page 7/18