DMS-30LCD Series
3½ Digit, LCD Display Digital Panel Voltmeters
FEATURES
Large (0.4"/10.2mm), enhanced-contrast, LCD display
Single +5V supply or 9V battery
Power as low as 3.2mW
Miniature size:
2.17" x 0.92" x 0.43" (55mm x 23mm x 11mm)
Epoxy-encapsulated, 12-pin DIP
Backlit displays optional
4 differential input voltage ranges
High accuracy, ±1 count (±0.05%)
Autopolarity changeover and overrange indication
User-selectable decimal point placement
Numerous "plug-on" application boards
0 to +60°C temperature range
Offering all the outstanding features and benefits of Murata Power Solutions’ industry
leading DMS-20LCD Series of 3½ Digit LCD Panel Meters, DMS-30LCD meters offer larger,
more easily readable displays at slightly higher power consumptions. Like all DMS Series
LCD meters, these miniature (2.17” x 0.92” x 0.43”), epoxy-encapsulated devices offer
component-like ease-of-use, outstanding reliability and easy installation in either panels or
pc-cards.
DMS-30LCD devices operate from a single +5V supply or a 9V battery. Battery-oper-
ated units typically draw 350μA and consume a mere 3.2mW. Backlit models are available
for low-light applications; though we have found many designers prefer Murata Power
Solutions’ unique low-power LED meters in those circumstances.
Offering 4 optional input voltage ranges (±200mV, ±2V, ±20V or ±200V), DMS-30LCD
meters have an extremely user-friendly input structure. They can be used in differential
or single-ended modes. Input impedance is a minimum 800kΩ. CMRR is typically 86dB.
CMV is ±2V, and inputs are overvoltage protected to ±100V.
Each meter incorporates an extremely stable, double regulated reference and is fully
calibrated at our factory prior to encapsulation. We guarantee outstanding initial accuracy
(±1 count) and excellent stability over temperature (±0.15 counts/°C). These extremely
rugged meters are moisture and vibration proof and never require adjustment or recalibra-
tion.
For popular applications (4-to-20mA, rms-to-dc conversion, ac line power, J and K
thermocouples, etc.), the DMS-30LCD Series includes a complete line of "plug-on" applica-
tion boards that conveniently convert your meter into an application-specific instrument.
+5V SUPPLY/ 1
+BATTERY
3 DISPLAY TEST/ 2
BACKLIGHT
5V RETURN/ 3
–BATTERY
4
DP 3
+5V
V+
–5V
DC/DC 2
CONVERTER
V–
J1
0 Vdc
A/D
CONVERTER
DATA
0.01µF
+2.0V
1.23V
REF.
R2 1
12
(–) INPUT LO
R1
909k
11
(+) INPUT HI
10 ANALOG
COMMON
1.82k
9
+1.23V REFERENCE OUT
5
DP 2
6
DP 1
8
REFERENCE OUT
+5V
7
REFERENCE IN
1 R2 is not used on ±200mV (-0) models or ±2V (-1) models.
 
R2 = 100k on ±20V (-2) models and 9.1k on ±200V (-3) models.
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com/support
2 DC/DC converter is not used on 9V-powered models,
J1 is connected.
3 Display Test function is not available on backlit models.
MPM_DMS30LCD.E01 Page 1 of 6