DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MAX5417 查看數據表(PDF) - Maxim Integrated

零件编号
产品描述 (功能)
生产厂家
MAX5417 Datasheet PDF : 14 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
256-Tap, Nonvolatile, I2C-Interface,
Digital Potentiometers
TIMING CHARACTERISTICS (continued)
(VDD = +2.7V to +5.25V, H = VDD, L = GND, TA = -40°C to +85°C, unless otherwise noted. Typical values are at VDD = +5V, TA =
+25°C. See Figures 1 and 2.) (Note 7)
PARAMETER
Data Setup Time
Data Hold Time
SDA, SCL Rise Time
SDA, SCL Fall Time
Setup Time for STOP Condition
Bus Free Time Between STOP
and START Condition
Pulse Width of Spike Suppressed
Maximum Capacitive Load for
Each Bus Line
Write NV Register Busy Time
SYMBOL
tSU-DAT
tHD-DAT
tR
tF
tSU-STO
CONDITIONS
tBUF Minimum power-up rate = 0.2V/ms
tSP
CB
(Note 9)
tBUSY (Note 10)
MIN TYP MAX UNITS
100
ns
0
0.9
µs
300
ns
300
ns
0.6
µs
1.3
µs
50
ns
400
pF
12
ms
Note 1: The DNL and INL are measured with the potentiometer configured as a voltage-divider with H = VDD and L = GND. The
wiper terminal is unloaded and measured with a high-input-impedance voltmeter.
Note 2: The DNL and INL are measured with the potentiometer configured as a variable resistor. H is unconnected and L = GND.
For the 5V condition, the wiper terminal is driven with a source current of 80µA for the 50kconfiguration, 40µA for the
100kconfiguration, and 20µA for the 200kconfiguration. For the 3V condition, the wiper terminal is driven with a source
current of 40µA for the 50kconfiguration, 20µA for the 100kconfiguration, and 10µA for the 200kconfiguration.
Note 3: The wiper resistance is measured using the source currents given in Note 2. For operation to VDD = 2.7V, see Wiper
Resistance vs. Temperature in the Typical Operating Characteristics.
Note 4: The device draws higher supply current when the digital inputs are driven with voltages between (VDD - 0.5V) and (GND +
0.5V). See Supply Current vs. Digital Input Voltage in the Typical Operating Characteristics.
Note 5: Wiper at midscale with a 10pF load (DC measurement). L = GND; an AC source is applied to H; and the W output is mea-
sured. A 3dB bandwidth occurs when the AC W/H value is 3dB lower than the DC W/H value.
Note 6: The programming current operates only during power-up and NV writes.
Note 7: SCL clock period includes rise and fall times tR and tF. All digital input signals are specified with tR = tF = 2ns and timed
from a voltage level of (VIL + VIH) / 2.
Note 8: Wiper settling time is the worst-case 0% to 50% rise time measured between consecutive wiper positions. H = VDD,
L = GND, and the wiper terminal is unloaded and measured with a 10pF oscilloscope probe (see the Typical Operating
Characteristics for the tap-to-tap switching transient).
Note 9: An appropriate bus pullup resistance must be selected depending on board capacitance. Refer to the document linked to
this web address: www.semiconductors.philips.com/acrobat/literature/9398/39340011.pdf.
Note 10: The idle time begins from the initiation of the stop pulse.
4 _______________________________________________________________________________________

Share Link: 