±1°C, SMBus-Compatible Remote/Local
Temperature Sensor with Overtemperature Alarm
Table 3. Command-Byte Assignments
ADDRESS
POR STATE
F U N C T IO N
00h 00h (0000 0000)
Read local temperature
01h 00h (0000 0000)
Read remote temperature
02h N/A
Read status byte
03h 10h (0001 0000)
Read configuration byte
05h 46h (0100 0110) +70°C Read local high limit
07h 78h (0111 1000) +120°C Read remote high limit
09h N/A
Write configuration byte
0Bh N/A
Write local high limit
0Dh N/A
Write remote high limit
0Fh N/A
Single shot
10h 0000 0000
Read remote extended
temperature
11h 0000 0000
Read internal extended
temperature
FEh 4Dh (0100 1101)
Read manufacturer ID
(0001 100). Following such a broadcast, any slave
device that generated an interrupt attempts to identify
itself by putting its own address on the bus.
The alert response can activate several different slave
devices simultaneously, similar to the I2C General Call.
If more than one slave attempts to respond, bus arbitra-
tion rules apply, and the device with the lower address
code wins. The losing device does not generate an
acknowledge and continues to hold the ALERT line low
until cleared. (The conditions for clearing an ALERT
vary depending on the type of slave device.)
Successful completion of the alert response protocol
clears the interrupt latch. If the condition still exists, the
device reasserts the ALERT interrupt at the end of the
next conversion.
Command Byte Functions
The 8-bit command byte register (Table 3) is the master
index that points to the various other registers within the
MAX6642. The registers POR state is 0000 0000, so a
Receive Byte transmission (a protocol that lacks the
Table 4. Configuration-Byte Bit Assignments
BIT
7 (MSB)
6
NAME
MASK1
STOP/RUN
POR STATE
0
0
5
External only
0
4
3 to 0
Fault
queue
1
0000
FUNCTION
A 1 masks off (disables) the ALERT interrupts.
A 1 puts the MAX6642 into standby mode.
A 1 disables local temperature measurements so that only
remote temperature is measured. The measurement rate
becomes 8Hz.
0: ALERT is set by a single fault. 1: Two consecutive faults
are required to set ALERT.
Reserved.
Table 5. Status-Byte Bit Assignments
BIT
7 (MSB)
NAME
BUSY
POR STATE
0
6
LHIGH
0
5
0
4
RHIGH
0
3
0
2
OPEN
0
1 to 0
0
FUNCTION
A 1 indicates the MAX6642 is busy converting.
A 1 indicates an internal high-temperature fault. Clear
LHIGH with a POR or by reading the status byte.
Reserved.
A 1 indicates an external high-temperature fault. Clear
RHIGH with a POR or by reading the status byte.
Reserved.
A 1 indicates a diode open condition. Clear OPEN with a
POR or by reading the status byte when the condition no
longer exists.
Reserved.