MB89810A Series
2. Recommended Operating Conditions
Parameter
Power supply voltage
“H” level voltage
“L” level voltage
Open-drain output pin
application voltage
Operating temperature
Symbol
VCC
VIH
VIHS
VIHS2
VIL
VILS
Value
Min.
Max.
2.2*
6.0
2.7*
6.0
1.5
6.0
0.7 VCC VCC + 0.3
0.8 VCC VCC + 0.3
0.8 VCC VSS + 6.0
VSS – 0.3 0.3 VCC
VSS – 0.3 0.2 VCC
Unit
V
V
V
V
V
V
V
V
(VSS = 0.0 V)
Remarks
Normal operation assurance range
MB89816A
Normal operation assurance range
MB89P817A
Retains the RAM state in stop mode
P00 to P07, P10 to P17, P30 to P37,
P40 to P47, P50 to P54
(with pull-up resistor)
RST, MOD0, MOD1, P60 to P67,
Pheripheral input for port 3 and port 4
P50 to P54 (without pull-up resistor)
P00 to P07, P10 to P17, P30 to P37,
P40 to P47, P50 to P54
RST, MOD0, MOD1, P60 to P67,
Pheripheral input for port 3 and port4
VD
VSS – 0.3 VSS + 6.0 V P50 to P54 (without pull-up resistor)
TA
–40
+85
°C
* : These values vary with the operating frequency. See Figure 1.
6
5
Operating assurance range
4
3
2
1
1.0
2.0
3.0
4.0
5.0
Main clock operating frequency (MHz) (at an instruction cycle of 4/FCH)
Note: The shaded area is assured only for the MB89816A
Figure 1 Operating Voltage vs. Main Clock Operating Frequency (for MB89816A)
20