DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MMSF7P03HD 查看數據表(PDF) - Motorola => Freescale

零件编号
产品描述 (功能)
生产厂家
MMSF7P03HD Datasheet PDF : 10 Pages
1 2 3 4 5 6 7 8 9 10
MMSF7P03HD
di/dt = 300 A/µs
Standard Cell Density
trr
High Cell Density
trr
ta
tb
t, TIME
Figure 11. Reverse Recovery Time (trr)
SAFE OPERATING AREA
The Forward Biased Safe Operating Area curve (Figure
12) defines the maximum simultaneous drain–to–source vol-
tage and drain current that a transistor can handle safely
when it is forward biased. Curves are based upon maximum
peak junction temperature and a case temperature (TC) of
25°C. Peak repetitive pulsed power limits are determined by
using the thermal response data in conjunction with the pro-
cedures discussed in AN569, “Transient Thermal Resistance
– General Data and Its Use.”
Switching between the off–state and the on–state may tra-
verse any load line provided neither rated peak current (IDM)
nor rated voltage (VDSS) is exceeded, and that the transition
time (tr, tf) does not exceed 10 µs. In addition the total power
averaged over a complete switching cycle must not exceed
(TJ(MAX) – TC)/(RθJC).
A power MOSFET designated E–FET can be safely used
in switching circuits with unclamped inductive loads. For reli-
able operation, the stored energy from circuit inductance dis-
sipated in the transistor while in avalanche must be less than
the rated limit and must be adjusted for operating conditions
differing from those specified. Although industry practice is to
rate in terms of energy, avalanche energy capability is not a
constant. The energy rating decreases non–linearly with an
increase of peak current in avalanche and peak junction tem-
perature.
Although many E–FETs can withstand the stress of drain–
to–source avalanche at currents up to rated pulsed current
(IDM), the energy rating is specified at rated continuous cur-
rent (ID), in accordance with industry custom. The energy rat-
ing must be derated for temperature as shown in the
accompanying graph (Figure 13). Maximum energy at cur-
rents below rated continuous ID can safely be assumed to
equal the values indicated.
100
VGS = 12 V
SINGLE PULSE
10 TA = 25°C
1 ms
10 ms
1.0
dc
0.1
RDS(on) LIMIT
THERMAL LIMIT
PACKAGE LIMIT
0.01
0.1
1.0
10
100
VDS, DRAIN–TO–SOURCE VOLTAGE (VOLTS)
Figure 12. Maximum Rated Forward Biased
Safe Operating Area
5000
4500
4000
ID = 7.0 A
3500
3000
2500
2000
1500
1000
500
0
25
45
65
85
105
125
145
TJ, STARTING JUNCTION TEMPERATURE (°C)
Figure 13. Maximum Avalanche Energy versus
Starting Junction Temperature
6
Motorola TMOS Power MOSFET Transistor Device Data