DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MS4 查看數據表(PDF) - Crydom Inc.,

零件编号
产品描述 (功能)
生产厂家
MS4 Datasheet PDF : 20 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Panel Mount Solid State Relays - AC Output
HD60, HA60
25-125Amp
600 Vac
Zero Voltage or Random Turn-on
Ultra Low Control Current
CMD, CMA
25-125Amp
120/240/480/600 Vac
SCR AC Switch Output
Zero Cross or Random Turn-on
Crydom's HD60 (DC control) and HA60 (AC control) relays incorporate the same
proven technologies as the HD/HA products with up to 660 Vac load voltage
range, preferred choice in Canada. All models come with 1200 volts blocking as
standard and are available in either zero-cross or random turn-on and phase
controllable (-10) switching versions.
HD6025
HD6050
HD6090
HD60125
Line
Voltage
Range
Vrms
48-660
48-660
48-660
48-660
Load
Current
Range
Arms
.04-25
.04-50
.04-90
.15-125
Control
Voltage
Range
Vdc
3-32
3-32
3-32
3-32
Control
Current
@ 5Vdc
mA
2.0
2.0
2.0
2.0
Must
Release
Voltage
Vdc
1.0
1.0
1.0
1.0
Surge
Current
1-Cycle
Apk
250
625
1200
1750
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA
Line
Voltage
Range
Vrms
Load
Current
Range
Arms
Control
Voltage
Range
Vrms
Control Must
Current Release
@120Vrms Voltage
mA
Vrms
Surge
Current
1-Cycle
Apk
HA6025
HA6050
HA6090
HA60125
48-660 .04-25 90-280 2.0
48-660 .04-50 90-280 2.0
48-660 .04-90 90-280 2.0
48-660 .15-125 90-280 2.0
10.0 250 UL, CSA, VDE
10.0 625 UL, CSA, VDE
10.0 1200 UL, CSA, VDE
10.0 1750 UL, CSA
Operating Temperature Range: -40˚C to 80˚C, Isolation Voltage: 4000 Vrms, Minimum Off-State dv/dt: 500V/μsec
24 Vac input versions available (E suffix)
PRG
150Amp
120/240/480 Vac
SCR AC Switch Output
High Steady-State Current
Internal Snubber
Designed for the most demanding application, the PRG SPST-NO Solid State
Relays offer an exceptionally high (150 Arms current rating). They are designed
for a wide range of applications including; high-intensity incandescent lamp
dimming, motor speed control, reversing and switching, heater or pump controls
and more.
Line
Voltage
Range
Vrms
PRGD24150 24-280
PRGD24150-10 24-280
PRGD48150 48-530
PRGD48150-10 48-530
Load
Current
Range
Arms
.15-150
.15-150
.15-150
.15-150
Control
Voltage
Range
Vdc
3-15
3-15
4-15
4-15
Control
Current
@ 5Vdc
mA
15
15
15
15
Must Surge
Release Current
Voltage 1-Cycle
Vdc Apk
1.0 1750
1.0 1750
1.0 1750
1.0 1750
Line
Voltage
Range
Vrms
Load
Current
Range
Arms
Control
Voltage
Range
Vrms
Control Must Surge
Current Release Current
@ 120Vrms Voltage 1-Cycle
mA
Vrms Apk
PRGA24150 24-280 .15-150 90-140 10
10 1750
PRGA24150-10 24-280 .15-150 90-140 10
10 1750
PRGA48150 48-530 .15-150 90-140 10
10 1750
PRGA48150-10 48-530 .15-150 90-140 10
10 1750
-10 suffix denotes random turn-on.
Operating Temperature Range: -30˚C to 80˚C Isolation Voltage: 4000 Vrms
These Propack SPST-NO solid state relays offer box clamp connections for safety
and ease-of-use. The on-board LED provides visible status indication. Also
available with DIN rail mount and integral heat sink, (see CMR products on page 14).
Model choices include zero-voltage or random turn-on (phase controllable)
switching (add suffix -10).
CMD2425
CMD2450
CMD2475
CMD2490
CMD24110
CMD24125
Line
Voltage
Range
Vrms
24-280
24-280
24-280
24-280
24-280
24-280
CMD4825
CMD4850
CMD4875
CMD4890
CMD48110
CMD48125
48-530
48-530
48-530
48-530
48-530
48-530
CMD6025
CMD6050
CMD6075
CMD6090
CMD60110
CMD60125
48-660
48-660
48-660
48-660
48-660
48-660
Load
Current
Range
Arms
.15-25
.15-50
.25-75
.25-90
.25-110
.25-125
.15-25
.15-50
.25-75
.25-90
.25-110
.25-125
.15-25
.15-50
.25-75
.25-90
.25-110
.25-125
Control
Voltage
Range
Vdc
3-32
3-32
3-32
3-32
3-32
3-32
4-32
4-32
4-32
4-32
4-32
4-32
4-32
4-32
4-32
4-32
4-32
4-32
Control
Current
@ 5Vdc
mA
17
17
17
17
17
17
14
14
14
14
14
14
14
14
14
14
14
14
Must
Release
Voltage
Vdc
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
Surge
Current
1-Cycle
Apk
250
625
1000
1200
1500
1750
250
625
1000
1200
1500
1750
250
625
1000
1200
1500
1750
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA
UL, CSA
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA
UL, CSA
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA
UL, CSA
CMA2425
CMA2450
CMA2475
CMA2490
CMA24110
CMA24125
Line
Voltage
Range
Vrms
24-280
24-280
24-280
24-280
24-280
24-280
Load
Current
Range
Arms
.15-25
.15-50
.25-75
.25-90
.25-110
.25-125
Control
Voltage
Range
Vrms
90-140
90-140
90-140
90-140
90-140
90-140
Control Must
Current Release
@120Vrms Voltage
mA
Vrms
15
10
15
10
15
10
15
10
15
10
15
10
Surge
Current
1-Cycle
Apk
250
625
1000
1200
1500
1750
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA
UL, CSA
CMA4825 48-530 .15-25 90-140 15
10
250
UL, CSA, VDE
CMA4850 48-530 .15-50 90-140 15
10
625
UL, CSA, VDE
CMA4875 48-530 .25-75 90-140 15
10
1000 UL, CSA, VDE
CMA4890 48-530 .25-90 90-140 15
10
1200 UL, CSA, VDE
CMA48110 48-530 .25-110 90-140 15
10
1500 UL, CSA
CMA48125 48-530 .25-125 90-140 15
10
1750 UL, CSA
CMA6025 48-660 .15-25 90-140 15
10
250
UL, CSA, VDE
CMA6050 48-660 .15-50 90-140 15
10
625
UL, CSA, VDE
CMA6075 48-660 .25-75 90-140 15
10
1000 UL, CSA, VDE
CMA6090 48-660 .25-90 90-140 15
10
1200 UL, CSA, VDE
CMA60110 48-660 .25-110 90-140 15
10
1500 UL, CSA
CMA60125 48-660 .25-125 90-140 15
10
1750 UL, CSA
Operating Temperature Range: -40˚C to 80˚C, Isolation Voltage: 4000 Vrms, Minimum Off-State dv/dt: 500V/μsec
24 Vac input versions available (E suffix)
10
Questions? Call or e-mail Americas +1 (877) 502 5500 sales@crydom.com
Europe +44 (0) 1202 606030 sales-europe@crydom.com

Share Link: 