74VCX163245
ABSOLUTE MAXIMUM RATINGS
Symbol
Parameter
Value
Unit
VCCA Supply Voltage
-0.5 to +4.6
V
VCCB Supply Voltage
-0.5 to +4.6
V
VI
DC Input Voltage
-0.5 to +4.6
V
VI/OA DC I/O Voltage (Output disabled)
-0.5 to +4.6
V
VI/OB DC I/O Voltage (Output disabled)
-0.5 to +4.6
V
VI/OA DC I/O Voltage
-0.5 to VCCA + 0.5
V
VI/OB DC I/O Voltage
-0.5 to VCCB + 0.5
V
IIK
DC Input Diode Current
− 20
mA
IOK
DC Output Diode Current
− 50
mA
IOA
DC Output Current
± 50
mA
IOB
DC Output Current
± 50
mA
ICCA DC VCC or Ground Current
± 100
mA
ICCB DC VCC or Ground Current
± 100
mA
Pd
Power Dissipation
400
mW
Tstg
Storage Temperature
-65 to +150
°C
TL
Lead Temperature (10 sec)
300
°C
Absolute Maximum Rating are those value beyond which damage to the device may occur. Functional operation under these condition is not
implied
(*) 500mW: ≅ 65°C derated to 300mW by 10mW/°C: 65°C to 85°C
RECOMMENDED OPERATING CONDITIONS
Symbol
Parameter
VCCA Supply Voltage
VCCB Supply Voltage
VI
Input Voltage (Dir, OE)
VI/OA I/O Voltage
VI/OB
Top
I/O Voltage
Operating Temperature
dt/dv Input Rise and Fall Time (note 1)
1) VIN from 0.8V to 2.0V at VCC =3.0V
Value
2.3 to 3.6
1.65 to 2.7
0 to VCCB
0 to VCCA
0 to VCCB
-40 to 85
0 to 10
Unit
V
V
V
V
V
°C
ns/V
4/15