DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

VN750SMP-E 查看數據表(PDF) - STMicroelectronics

零件编号
产品描述 (功能)
生产厂家
VN750SMP-E
ST-Microelectronics
STMicroelectronics ST-Microelectronics
VN750SMP-E Datasheet PDF : 27 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
VN750SMP-E
Electrical specifications
2.5.2
Solution 2: diode (DGND) in the ground line
A resistor (RGND=1 kΩ) should be inserted in parallel to DGND if the device drives an
inductive load.
This small signal diode can be safely shared amongst several different HSDs. Also in this
case, the presence of the ground network produces a shift (600mV) in the input threshold
and in the status output values if the microprocessor ground is not common to the device
ground. This shift not varies if more than one HSD shares the same diode/resistor network.
Series resistor in input and status lines are also required to prevent that, during battery
voltage transient, the current exceeds the absolute maximum rating.
Safest configuration for unused input and status pin is to leave them unconnected.
2.6
Load dump protection
Dld is necessary (voltage transient suppressor) if the load dump peak voltage exceeds the
VCC max DC rating. The same applies if the device is subject to transients on the VCC line
that are greater than the ones shown in the ISO T/R 7637/1 table.
2.7
Microcontroller I/Os protection
If a ground protection network is used and negative transient are present on the VCC line,
the control pins is pulled negative. ST suggests to insert a resistor (Rprot) in line to prevent
the µC I/Os pins to latch-up.
The value of these resistors is a compromise between the leakage current of µC and the
current required by the HSD I/Os (Input levels compatibility) with the latch-up limit of µC
I/Os.
-VCCpeak/Ilatchup Rprot (VOHµC-VIH-VGND) / IIHmax
Calculation example:
For VCCpeak= - 100 V and Ilatchup 20 mA; VOHµC 4.5 V
5 kΩ ≤ Rprot 65 kΩ.
Recommended values: Rprot =10 kΩ.
2.8
Open-load detection in off-state
Off-state open-load detection requires an external pull-up resistor (RPU) connected between
output pin and a positive supply voltage (VPU) like the +5 V line used to supply the
microprocessor.
The external resistor has to be selected according to the following requirements:
1. no false open-load indication when load is connected: in this case we have to avoid
VOUT to be higher than VOlmin; this results in the following condition
VOUT=(VPU/(RL+RPU))RL<VOlmin.
2. no misdetection when load is disconnected: in this case the VOUT has to be higher than
VOLmax; this results in the following condition RPU<(VPU–VOLmax)/IL(off2).