DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

AD8174AN 查看數據表(PDF) - Analog Devices

零件编号
产品描述 (功能)
生产厂家
AD8174AN Datasheet PDF : 16 Pages
First Prev 11 12 13 14 15 16
AD8170/AD8174
IN0
75
1 +1
AD8174
+VS 14
0.1µF
+
10µF
+5V
IN1
75
2 GND
3 +1
IN2
75
0.1µF
4 GND 2
5 +1
–5V
+
6 –VS
10µF
7 +1
2
IN3
75
13
549
12
SD
11
+5V
ENABLE
10
A1
9
A0
8
549
RBT
75
VOUT
A2
RT*
A1
RT*
IN4
75
1 +1
AD8174
+VS 14
0.1µF
+
10µF
+5V
IN5
75
2 GND
3 +1
IN6
75
0.1µF
4 GND 2
5 +1
–5V
+
6 –VS
10µF
7 +1
2
IN7
75
13
549
12
SD
11
+5V
ENABLE
10
A1
9
A0
8
549
*OPTIONAL
A0
RT*
Figure 26. 8-to-1 Multiplexer
Color Document Scanner
Charge Coupled Devices (CCDs) find widespread use in
scanner applications. A monochrome CCD delivers a serial
stream of voltage levels, each level being proportional to the
light shining on that cell. In the case of the color image scanner
shown, there are three output streams, representing red, green
and blue. Interlaced with the stream of voltage levels is a voltage
representing the reset level (or black level) of each cell. A
Correlated Double Sampler (CDS) subtracts these two voltages
from each other in order to eliminate the relatively large offsets
which are common with CCDs.
The next step in the data acquisition process involves digitizing
the three signal streams. Assuming that the analog to digital
converter chosen has a fast enough sample rate, multiplexing the
three streams into a single ADC is generally more economic
than using one ADC per channel. In the example shown, the
AD8174 is used to multiplex the red, green and blue channels
into the AD876, an 8- or 10-bit 20 MSPS ADC. Because of its
high bandwidth, the AD8174 is capable of driving the switched
capacitor input stage of the AD876 without additional buffering.
In addition to the bandwidth, it is necessary to consider the
settling time of the multiplexer. In this case, the ADC has a
sample rate of 20 MHz which corresponds to a sampling
period of 50 ns. Typically, one phase of the sampling clock is
used for conversion (i.e., all levels are held steady) and the other
phase is used for switching and settling to the next channel.
Assuming a 50% duty cycle, the signal chain must settle within
25 ns. With a settling time to 0.1% of 15 ns, the multiplexer
easily satisfies this criterion.
In the example shown, the fourth (spare) channel of the
AD8174 is used to measure a reference voltage. This voltage
would probably be measured less frequently than the R, G and
B signals. Multiplexing a reference voltage offers the advantage
that any temperature drift effects caused by the multiplexer will
equally impact the reference voltage and the to-be-measured
signals. If the fourth channel is unused, it is good design
practice to tie the input permanently to ground.
CONTROL AND TIMING
R
CDS
G
CCD
CDS
B
CDS
REFERENCE
A0 A1 SD ENABLE
IN0
AD8174
IN1
VOUT
IN2
IN3
–VIN
1k
(G = +1)
AD876
8/10-BIT
20MSPS
A/D
Figure 27. Color Document Scanner
REV. 0
–11–

Share Link: 