DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

ACPL-M43T 查看數據表(PDF) - Avago Technologies

零件编号
产品描述 (功能)
生产厂家
ACPL-M43T Datasheet PDF : 9 Pages
1 2 3 4 5 6 7 8 9
Recommended reflow condition as per JEDEC Standard, J-STD-020 (latest revision).
Note: Non-halide flux should be used.
Regulatory Information
The ACPL-M43T is approved by the following organizations:
UL
IEC/EN/DIN EN 60747-5-2
Approved under UL 1577, component recognition pro-
gram up to VISO = 4000 VRMS
CSA
Approved under CSA Component Acceptance Notice #5.
Approved under:
IEC 60747-5-5:2007
EN 60747-5-2:2001 + A1
DIN EN 60747-5-2 (VDE 0884 Teil 2)
IEC/EN/DIN EN 60747-5-2 Insulation Characteristics*
Description
Symbol
Characteristic Unit
Installation classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤ 150 Vrms
for rated mains voltage ≤ 300 Vrms
for rated mains voltage ≤ 600 Vrms
I – IV
I – III
I – II
Climatic Classification
55/125/21
Pollution Degree (DIN VDE 0110/1.89)
2
Maximum Working Insulation Voltage
VIORM
567
Vpeak
Input to Output Test Voltage, Method b*
VPR
VIORM x 1.875=VPR, 100% Production Test with tm=1 sec, Partial discharge < 5 pC
1063
Vpeak
Input to Output Test Voltage, Method a*
VIORM x 1.6=VPR, Type and Sample Test, tm=10 sec, Partial discharge < 5 pC
VPR
907
Vpeak
Highest Allowable Overvoltage (Transient Overvoltage tini = 60 sec)
VIOTM
6000
Vpeak
Safety-limiting values – maximum values allowed in the event of a failure.
Case Temperature
Input Current
Output Power
TS
175
°C
IS, INPUT
230
mA
PS, OUTPUT 600
mW
Insulation Resistance at TS, VIO = 500 V
RS
>109
* Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section, (IEC/EN/
DIN EN 60747-5-2) for a detailed description of Method a and Method b partial discharge test profiles.
Insulation and Safety Related Specifications
Parameter
Symbol ACPL-M43T Units
Minimum External
L(101)
5
mm
Air Gap (Clearance)
Minimum External
L(102)
5
mm
Tracking (Creepage)
Minimum Internal
Plastic Gap
(Internal Clearance)
0.08
mm
Tracking Resistance
CTI
175
V
(Comparative
Tracking Index)
Isolation Group
IIIa
(DIN VDE0109)
Conditions
Measured from input terminals to output
terminals, shortest distance through air.
Measured from input terminals to output
terminals, shortest distance path along body.
Through insulation distance conductor to
conductor, usually the straight line distance
thickness between the emitter and detector.
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0109)
3

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]