ADF7011
Parameter
PHASE-LOCKED LOOP
VCO Gain 433 MHz/868 MHz
Min
Typ
Max
40/80
Unit
MHz/V @ 868 MHz
Phase Noise (In-Band)5 433 MHz
Phase Noise (Out-of-Band)6
Phase Noise (In-Band)7 868 MHz
Phase Noise (Out-of-Band)8
Spurious9, 10
47–74, 87.5–118, 174–230, 470–862 MHz
9 kHz – 1 GHz
Above 1 GHz
Harmonics10
Second Harmonic, 433 MHz/868 MHz
Third Harmonic, 433 MHz/868 MHz
Other Harmonics, 433 MHz/868 MHz
–81
–90
–83
–95
–23/–28
–25/–29
–26/–40
–54
–36
–30
–20/–23
–22/–25
–23/–35
dBc/Hz @ 5 kHz offset
dBc/Hz @ 1 MHz offset
dBc/Hz @ 5 kHz offset
dBc/Hz @ 1 MHz offset
100 kHz loop BW
dBm
dBm
dBm. Assumes external harmonic filter.
dBc
dBc
dBc
REFERENCE INPUT
Crystal Reference
433 MHz
868 MHz
External Oscillator
Frequency
Input Level, High Voltage
Input Level, Low Voltage
FREQUENCY COMPENSATION
Pull In Range of Register
1.7
3.4
3.4
0.7 VDD
1
22.1184
22.1184
40
0.2 VDD
100
MHz
MHz
MHz
V
V
ppm
PA CHARACTERISTICS
RF Output Impedance
868 MHz
433 MHz
TIMING INFORMATION
Chip Enabled to Regulator Ready10
Crystal Oscillator to CLKOUT OK
4 MHz Crystal
22.1184 MHz Crystal
16 – j33
25 – j2.6
50
200
1.8
2.2
, ZREF = 50
, ZREF = 50
µs
ms
ms
TEMPERATURE RANGE – TA
–40
+85
ЊC
NOTES
1Operating temperature range is as follows: –40ЊC to +85ЊC.
2Datarates should be limited to adhere to edge of band requirements in accordance with ETSI 300-220
3Frequency Deviation = (PFD Frequency ؋ Mod Deviation )/212.
GFSK Frequency Deviation = (PFD Frequency ؋ 2m)/212 where m = Mod Control.
4 The output power is limited by the spurious requirements of ETSI at +55 ЊC. The addition of an output filter (see Applications section) will allow increased output
levels to >10 dBm at both 433 MHz and 868 MHz
5 VDD = 3 V, PFD = 4 MHz, PA = 10 dBm
6 VDD = 3 V, Loop Filter BW = 100 kHz
7 VDD = 3 V, PFD = 4.42368 MHz, PA = 3 dBm
8 VDD = 3 V, Loop Filter BW = 100 kHz
9 These spurious levels are based on a maximum output power of +3 dBm for 868 MHz and +10 dBm for 433 MHz. It assumes a PFD frequency of <5 MHz.
Recommended PFD frequencies are 4.42368 MHz (22.1184/5) for 868 MHz, and 4 MHz for 433 MHz operation. Compliance for higher output powers will require
an external filter. See Applications section.
10 Not production tested. Based on characterization.
Specifications subject to change without notice.
REV. 0