DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MC-4532CC727PF-A75 查看數據表(PDF) - NEC => Renesas Technology

零件编号
产品描述 (功能)
生产厂家
MC-4532CC727PF-A75
NEC
NEC => Renesas Technology NEC
MC-4532CC727PF-A75 Datasheet PDF : 16 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
MC-4532CC727
DC Characteristics (Recommended Operating Conditions Unless Otherwise Noted)
Parameter
Symbol
Test condition
5 Operating current
ICC1 Burst length = 1
/CAS latency = 2
tRC tRC(MIN.), IO = 0 mA
/CAS latency = 3
Precharge standby current in ICC2P CKE VIL(MAX.), tCK = 15 ns
5 power down mode
ICC2PS CKE VIL(MAX.), tCK =
Precharge standby current in ICC2N CKE VIH(MIN.), tCK = 15 ns, /CS VIH(MIN.),
non power down mode
Input signals are changed one time during 30 ns.
ICC2NS CKE VIH(MIN.), tCK =
Input signals are stable.
Active standby current in
ICC3P CKE VIL(MAX.), tCK = 15 ns
power down mode
ICC3PS CKE VIL(MAX.), tCK =
Active standby current in
ICC3N CKE VIH(MIN.), tCK = 15 ns, /CS VIH(MIN.),
non power down mode
Input signals are changed one time during 30 ns.
MIN. MAX. Unit Notes
1,170 mA 1
1,215
18 mA
18
360 mA
144
90 mA
72
540 mA
5 Operating current
ICC3NS CKE VIH(MIN.), tCK = , Input signals are stable.
ICC4 tCK tCK(MIN.)
/CAS latency = 2
360
1,350 mA 2
(Burst mode)
5 CBR (Auto) refresh current
5
ICC5
IO = 0 mA
tRC tRC(MIN.)
/CAS latency = 3
/CAS latency = 2
/CAS latency = 3
1,665
2,340 mA 3
2,430
Self refresh current
ICC6 CKE 0.2 V
36 mA
Input leakage current
II(L) VI = 0 to 3.6 V, All other pins not under test = 0 V
– 18 + 18 µA
CKE1 –500 +500 µA
Output leakage current
IO(L) DOUT is disabled, VO = 0 to 3.6 V
– 3 + 3 µA
High level output voltage
VOH IO = – 4.0 mA
2.4
V
Low level output voltage
VOL IO = + 4.0 mA
0.4 V
Notes 1. ICC1 depends on output loading and cycle rates. Specified values are obtained with the output open. In
addition to this, ICC1 is measured on condition that addresses are changed only one time during tCK (MIN.).
2. ICC4 depends on output loading and cycle rates. Specified values are obtained with the output open. In
addition to this, ICC4 is measured on condition that addresses are changed only one time during tCK (MIN.).
3. ICC5 is measured on condition that addresses are changed only one time during tCK (MIN.).
6
Data Sheet M14277EJ2V0DS00

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]