DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

B32671P(2012) 查看數據表(PDF) - EPCOS AG

零件编号
产品描述 (功能)
生产厂家
B32671P Datasheet PDF : 24 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
B32671P ... B32673P
Power Factor Correction
Technical data
Operating temperature
range
Dissipation factor tan δ
(in 10-3) at 20 °C
(upper limit values)
Insulation resistance Rins
at 100 V and 20 °C, rel.
humidity 65% (minimum
as-delivered values)
DC test voltage
Category voltage VC
(continuous operation with
VDC or VAC at f 1 kHz)
For 85 °C < TA the derating
is 1.28% per °C
Operating voltage Vop for
short operating periods
(VDC or VAC at f 1 kHz)
Reliability:
Failure rate λ
Service life tSL
Failure criteria:
Total failure
Failure due to variation
of parameters
Max. operating temperature Top, max
Upper category temperature Tmax
Lower category temperature Tmin
Rated temperature TR
1 kHz 1.0
10 kHz 2.5
100 kHz 25.0
> 30 G(CR 0.33 µF)
> 10000 s (CR > 0.33 µF)
+125 °C
+110 °C
55 °C
+85 °C
1.4  VR, 2 s
Top (°C)
DC voltage derating AC voltage derating
Top 85
VC = VR
VC,RMS = VRMS
85 < Top 100 VC = 0.81  VR
VC,RMS = 0.81  VRMS
100 < Top 110 VC = 0.68  VR
VC,RMS = 0.68  VRMS
110 < Top 125 VC = 0.5  VR
VC,RMS = 0.5  VRMS
TA (°C)
DC voltage (max. hours) AC voltage (max. hours)
TA 100
Vop = 1.1 × VC (1000 h) Vop = 1.0 × VC,RMS (1000 h)
110 < TA 125 Vop = 1.0 × VC (1000 h) Vop = 1.0 × VC,RMS (1000 h)
24 fit (1  10-7/h) at 0.5  VR, 40 °C
200000 h at 0.5  VR, 85 °C
For conversion to other operating conditions and temperatures, refer
to chapter "Quality, 2 Reliability"
Short circuit or open circuit
Capacitance change C/C
Dissipation factor tan δ
Insulation resistance Rins
Or time constant τ
> 10%
> 4 × upper limit values
< 150 M(CR 0.33 µF)
< 50 s (CR 0.33 µF)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 7 of 23

Share Link: 