BR200/201
POL Converter Module for 12 V System Intermediate Bus
RTRIM Constant Reference Value for Output Voltage
The output voltage level is set by the value of a resistance con-
nected to the RTRIM pin. The relationship is:
BR200: RTRIM (Ω) = (0.6 × 10,000) / (VOUT (V) – 0.6)
BR201: RTRIM (Ω) = (0.591 × 10,000) / (VOUT (V) – 0.591)
The following table provides representative values for RTRIM to
generate voltages within the specified VOUT ranges:
BR200
VOUT
(V)
RTRIM
(Ω)
1.65
5714
1.5
6666
1.2
10000
1
15000
0.95
17142
0.9
20000
0.75
40000
BR201
VOUT
(V)
RTRIM
(Ω)
3.63
1944
3.3
2181
2.5
3095
1.8
4888
1.6
5857
Input
Voltage (V)
Max. 0.5 V
0
0
Min. 100 ms
ON/OFF Pin
Voltage (V)
Max. 0.27 V
0
0
Min. 10 ms
Reset Conditions
There are two methods for resetting all functions in the
BR200/201 (refer to figure 6):
• Set VIN pin voltage to 0.5V or lower for a minimum of
100 ms, or
• Set the ON/¯O¯¯F¯F pin voltage to 0.27 V or lower for a minimum
of 10 ms
Figure 6. Reset conditions timing diagrams
Device resets
time (ms)
Device resets
time (ms)
BR200-DS, Rev. 0.2
7
SANKEN ELECTRIC CO., LTD.