SPECIFICATIONS
Table 2. ABSOLUTE MAXIMUM RATINGS
Parameter
Rating
Units
Operating Supply Voltage (VP VN)
Operating Temperature Range
6.0
V
–40 to +85
°C
Storage Temperature Range
–65 to +150
°C
DC Voltage at any Channel Input
(VN 0.5) to (VP + 0.5)
V
Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the
Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect
device reliability.
Table 3. STANDARD OPERATING CONDITIONS
Parameter
Operating Temperature Range
Rating
–40 to +85
Units
°C
Table 4. ELECTRICAL OPERATING CHARACTERISTICS (Note2)
Symbol
Parameter
Conditions
Min Typ Max
VP
Operating Supply Voltage (VPVN)
IP
Operating Supply Current
VF
Diode Forward Voltage
Top Diode
Bottom Diode
(VPVN) = 3.3 V
IF = 8 mA; TA = 25°C
3.3
5.5
8.0
0.60 0.80 0.95
0.60 0.80 0.95
ILEAK
CIN
DCIN
CMUTUAL
Channel Leakage Current
Channel Input Capacitance
Channel Input Capacitance Matching
Mutual Capacitance between signal pin
and adjacent signal pin
TA = 25°C; VP = 5 V, VN = 0 V, VIN = 0 V to 5 V
At 1 MHz, VP = 3.3 V, VN = 0 V, VIN = 1.65 V
At 1 MHz, VP = 3.3 V, VN = 0 V, VIN = 1.65 V
At 1 MHz, VP = 3.3 V, VN = 0 V, VIN = 1.65 V
±0.1 ±1.0
0.80 1.2
0.02
0.15
VESD
Insystem ESD Protection
Peak Discharge Voltage at any
channel input, in system
a) Contact discharge per
TA = 25°C (Notes 4 and 5)
±8
IEC 6100042 standard
b) Human Body Model,
TA = 25°C (Notes 3 and 5)
±15
MILSTD883, Method 3015
VCL Channel Clamp Voltage
Positive Transients
Negative Transients
TA = 25°C, IPP = 1A, tP = 8/20 mS
(Note 5)
+9.8
–1.8
RDYN Dynamic Resistance
IPP = 1 A, tP = 8/20 mS
Positive Transients
Any I/O pin to Ground (Note 5)
0.76
Negative Transients
0.56
2. All parameters specified at TA = –40°C to +85°C unless otherwise noted.
3. Human Body Model per MILSTD883, Method 3015, CDischarge = 100 pF, RDischarge = 1.5 KW, VP = 3.3 V, VN grounded.
4. Standard IEC 6100042 with CDischarge = 150 pF, RDischarge = 330 W, VP = 3.3 V, VN grounded.
5. These measurements performed with no external capacitor on VP.
6. Measured under pulsed conditions, pulse width = 0.7 ms, maximum current = 1.5 A.
Units
V
mA
V
mA
pF
pF
pF
kV
V
W
http://onsemi.com