LLiInNeEReRgEuGlaUtioLnA T I O N
+5V Line Regulation
(+5V output loaded @ 2.75A, ±12V outputs loaded @ ±250mA )
+5.010
+5.005
+5.000
+4.995
+4.990
+4.985
+4.980
+4.975
18 24
36
48
60
72
Input Voltage (Volts)
+12V Line Regulation
(+5V output loaded @ 2.75A, ±12V outputs loaded @ ±250mA )
+12.150
+12.125
+12.100
+12.075
+12.050
+12.025
+12.000
+11.975
18 24
36
48
60
72
Input Voltage (Volts)
–12V Line Regulation
(+5V output loaded @ 2.75A, ±12V outputs loaded @ ±250mA )
–12.025
–12.050
–12.075
–12.100
–12.125
–12.150
–12.175
–12.200
18 24
36
48
60
72
Input Voltage (Volts)
20W, TRIPLE OUTPUT DC/DC CONVERTERS
EMI RADIATED EMISSIONS
If you’re designing with EMC in mind, note that all of DATEL’s TWR 20 Watt
A-Series DC/DC Converters have been characterized for radiated and con-
ducted emissions in our new EMI/EMC laboratory. Testing is conducted in an
EMCO 5305 GTEM test cell utilizing EMCO automated EMC test software.
Radiated emissions are tested to the limits of FCC Part 15, Class B and
CISPR 22 (EN 55022) Class B. Correlation to other specifications can be
supplied upon request. Radiated emissions plots to FCC and CISPR 22 for
model TWR-5/3000-15/500-D12A appear below. Its performance is typical of
all models in the Series. Published EMC test reports are available for each
model number. Contact DATEL’s Applications Engineering for details.
TWR-5/3000-15/500-D12A Radiated Emissions
FCC Part 15 Class B, 3 Meters
Converter Output = +5Vdc @ 2.7A and ±15Vdc @ ±450mA
80
70
60
FCC Class B Limit
50
40
30
20
10
0
Radiated Emissions
–10
–20
100
Frequency (MHz)
1000
TWR-5/3000-15/500-D12A Radiated Emissions
EN 55022 Class B, 10 Meters
Converter Output = +5Vdc @ 2.7A and ±15Vdc @ ±450mA
80
70
60
50
EN 55022 Class B Limit
40
30
20
10
0
Radiated Emissions
–10
–20
100
Frequency (MHz)
1000
6
Downloaded from DatasheetLib.com - datasheet search engine