First Prev 11 12
Head Directions
The head can be mounted in four directions. To remove the head,
turn the head by 45° as shown in figures A and B below.
To change the direction of the head, make sure that the protruding
part of the rotating lever engages with the groove of the plunger.
Then turn the head clockwise or counterclockwise to the desired
direction. At that time, make sure that the groove of the plunger is
located under the rotating lever. If the direction of the head is not set
when the plunger is rotated by 45°, the groove of the plunger presses
the rotating lever. The head, plunger, or the built-in switch may be
damaged as a result.
Head Direction Changes
Left
Front
(45)
(45)
(A)
(B)
Back
Head Bottom View
Right
Switch Top View
Operation plunger and
groove mechanism
Rotation lever and
protruding part
Normal Positions of Rotating Lever and Plunger
Switch body
Rotating lever (with
protruding part)
Plunger (with groove)
Built-in switch
Be sure to check the mechanical lock and solenoid release functions
when mounting the D4BL.
If the head direction is changed, recheck the tightening torque of
each of screw. Make sure that no foreign materials will penetrate
through the key hole on the head.
Mounting the Cover
When tightening the cover, first check the specified torque, and then
tighten each screw to the that torque. Also, make sure that no foreign
matter has entered the switch.
When mounting the cover, make sure that the cover and switch box
are properly aligned.
D-146
Safety Sensors / Components