Approved Standard Ratings
TÜV (EN60947-5-1)
Item
Utilization category
Rated operating current (Ie)
Rated operating voltage (Ue)
Standard model Indicator model
AC-15
AC-15
3A
6A
250 V
115 V
Use a 10-A fuse type gI or gG that conforms to IEC269 as a short-circuit protection device.
UL/CSA (UL508, CSA C22.2 No. 14)
A300
Rated voltage
120 VAC
240 VAC
Carry current
10 A
60 A
30 A
Make
Current
6A
3A
Break
Note: The UL/CSA approved rating for products with indicators (-A) is 6 A/115 VAC.
Volt-amperes
Make
Break
7,200 VA
720 VA
Characteristics
Degree of protection
IP67 (See note 2.)
Durability (See note 3.)
Mechanical:1,000,000 operations min.
Electrical:500,000 operations min. (10-A resistive load at 250 VAC)
Operating speed
0.05 to 0.5 m/s
Operating frequency
30 operations/min max.
Rated frequency
50/60 Hz
Operating characteristics
Direct opening force:19.61 N min. (EN60947-5-1)
Direct opening travel:20 mm min. (EN60947-5-1)
All stroke:23 mm min.
Holding force
700 N min. (GS-ET-19)
Insulation resistance
100 MW min. (at 500 VDC)
Rated insulation voltage (Ui)
300 V (EN60947-5-1)
Conventional enclosed thermal current
(Ithe)
10 A (EN60947-5-1)
Dielectric strength (Uimp)
Impulse dielectric strength (Uimp) 4 kV (EN60947-5-1) between terminals of different polarity, be-
tween each terminal and ground, and between each terminal and non-current-carrying metal
part;
2.5 kV between solenoid and ground (EN60947-5-1)
Conditional short-circuit current
100 V (EN60947-5-1)
Pollution degree
(operating environment)
3 (EN60947-5-1)
Protection against electric shock
Class I (with ground terminal)
Switching overvoltage
1,500 V max. (EN60947-5-1)
Contact resistance
50 mW max. (initial value)
Vibration resistance
Malfunction: 10 to 55 Hz, 0.35-mm single amplitude
Shock resistance
Destruction:1,000 m/s2 min. (IEC68-2-27)
Malfunction:300 m/s2 min. (IEC68-2-27)
Ambient temperature
Operating:–10°C to 55°C (with no icing)
Ambient humidity
Operating:95% max.
Weight
Approx. 800 g
Note: 1. The above values are initial values.
2. Although the switch box is protected from dust, oil or water penetration, do not use the D4BL in places where dust, oil, water, or chemicals
may penetrate through the key hole on the head, otherwise Switch damage or malfunctioning may occur.
3. The durability is for an ambient temperature of 5°C to 35°C and an ambient humidity of 40% to 70%.