Characteristics
Degree of protection *1
IP67 (EN60947-5-1)
Durability *2
Mechanical
Electrical
1,000,000 operations min.
500,000 operations min. (10 A resistive load at 250 VAC)
Operating speed
0.1 m/s to 0.5 m/s
Operating frequency
30 operations/minute max.
Direct opening force *3
19.61 N min. (EN60947-5-1)
Direct opening travel *3
20 mm min. (EN60947-5-1)
Contact resistance
25 mΩ max.
Rated insulation voltage (Ui)
600 V (EN60947-5-1)
Rated frequency
50/60 Hz
Protection against electric shock
Class I (with ground terminal)
Pollution degree (operating environment) 3 (EN60947-5-1)
Impulse withstand
voltage
(EN60947-5-1)
Between terminals of
same polarity
Between terminals of
different polarity
Between each
terminal and ground
4 kV
Insulation resistance
100 MΩ min. (at 500 VDC) between terminals of same or different polarity, between each
terminal and ground, and between each terminal and non-current-carrying metal part
Contact gap
2 × 2 mm min.
Vibration
resistance
Malfunction
10 to 500 Hz, 0.65 mm single amplitude
Shock resistance
Destruction
Malfunction
1,000 m/s2 min. (IEC68-2-27)
300 m/s2 min. (IEC68-2-27)
Conditional short-circuit current
100 A (EN60947-5-1)
Conventional enclosed thermal current (Ithe) 20 A (EN60947-5-1)
Ambient operating temperature
40 to 80°C (with no icing)
Ambient operating humidity
95% max.
Weight
Approx. 285 g (D4BS-15FS)
Note: The above values are initial values.
*1. The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing properties are sufficient for
the operating conditions and environment beforehand. Although the switch box is protected from dust, oil, or water penetration, do not use the
D4BS in places where dust, oil, water, or chemicals may enter through the key hole on the head, otherwise Switch damage or malfunctioning
may occur.
*2. The durability is for an ambient temperature of 5 to 35°C and an ambient humidity of 40% to 70%. Contact your OMRON sales representative
for more detailed information on other operating environments.
*3. These figures are minimum requirements for safe operation.