DS1720
Higher resolutions may be obtained by reading the temperature, and truncating the 0.C bit (the LSB)
from the read value. This value is TEMP_READ. The value left in the counter may then be read by
issuing a READ COUNTER command. This value is the count remaining (COUNT_REMAIN) after the
gate period has ceased. The value of the slope accumulator may be read (using the READ SLOPE
command), yielding the number of counts per degree C (COUNT_PER_C) at that temperature. The actual
temperature may be then be calculated by the user using the following:
TEMPERATURE = TEMP_READ – 0.25 +
(COUNT_PER_C– COUNT_REMAIN)
COUNT_PER_C
DETAILED PIN DESCRIPTION Table 2
PIN SYMBOL DESCRIPTION
1
DQ
Data Input/Output pin for 3–wire communication port.
2
CLK/ CONV Clock input pin for 3–wire communication port. When the DS1720 is used in
a stand–alone application with no 3–wire port, this pin can be used as a
convert pin. Temperature conversion will begin on the falling edge of CONV .
3
RST
Reset input pin for 3–wire communication port.
4
GND
Ground pin.
5
TCOM
High/Low Combination Trigger. Goes high when temperature exceeds TH;
will reset to low when temperature falls below TL.
6
TLOW
Low Temperature Trigger. Goes high when temperature falls below TL.
7
THIGH
High Temperature Trigger. Goes high when temperature exceeds TH.
8
VDD
Supply Voltage. 2.7V – 5.5V input power pin.
OPERATION–THERMOSTAT CONTROLS
Three thermally triggered outputs, THIGH, TLOW, and TCOM, are provided to allow the DS1720 to be used
as a thermostat, as shown in Figure 3. When the DS1720’s temperature meets or exceeds the value stored
in the high temperature trip register, the output THIGH becomes active (high) and remains active until the
DS1720’s measured temperature becomes less than the stored value in the high temperature register, TH.
The THIGH output can be used to indicate that a high temperature tolerance boundary has been met or
exceeded, or as part of a closed loop system can be used to activate a cooling system and to deactivate it
when the system temperature returns to tolerance.
The TLOW output functions similarly to the THIGH output. When the DS1720’s measured temperature
equals or falls below the value stored in the low temperature register, the TLOW output becomes active.
TLOW remains active until the DS1720’s temperature becomes greater than the value stored in the low
temperature register, TL. The TLOW output can be used to indicate that a low temperature tolerance
boundary has been met or exceeded, or as part of a closed loop system, can be used to activate a heating
system and to deactivate it when the system temperature returns to tolerance.
The TCOM output goes high when the measured temperature meets or exceeds TH, and will stay high until
the temperature equals or falls below TL. In this way, any amount of hysteresis can be obtained.