DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

E6F-AG5C-C7202M 查看數據表(PDF) - OMRON Corporation

零件编号
产品描述 (功能)
生产厂家
E6F-AG5C-C7202M
Omron
OMRON Corporation Omron
E6F-AG5C-C7202M Datasheet PDF : 32 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
H8PS
Characteristics
Setting unit
Number of steps
Inputs
Encoder input
Encoder cable extension
distance
Output response time
Insulation resistance
Dielectric strength
Impulse withstand voltage
Noise immunity
Static immunity
Vibration Destruction
resistance Malfunction
Shock
Destruction
resistance Malfunction
Approved safety standards
EMC
Weight
0.5° increments at a resolution of 720, 1° increments at a resolution of 256 or 360 (See note 1.)
Up to 10 steps can be set for each cam to turn the output ON/OFF 10 times. (See note 2.)
Connections to a dedicated absolute encoder
Response rotation speed (in Run/Test Mode)
1600 r/min max. at a resolution of 256 or 360 (1200 r/min max. if ADV function is set for 4 or more cams)
(See notes 3 and 4.)
800 r/min max. at a resolution of 720 (600 r/min max. if ADV function is set for 4 or more cams)
Includes error data detection
256/360 resolution
100 m max. at 330 r/min or less
52 m max. at 331 to 1200 r/min (331 to 900 r/min if ADV function is set for 4 or more cams)
12 m max. at 1201 to 1600 r/min (901 to 1200 r/min if ADV function is set for 4 or more cams)
720 resolution
100 m max. at 330 r/min or less
52 m max. at 331 to 600 r/min (331 to 450 r/min if ADV function is set for 4 or more cams)
12 m max. at 601 to 800 r/min (451 to 600 r/min if ADV function is set for 4 or more cams)
0.3 ms max.
100 MΩ min. (at 500 VDC) between current-carrying terminals and exposed non-current-carrying metal
parts, between all current-carrying parts and the USB connector
1000 VAC, 50/60 Hz for 1 min between current-carrying terminals and exposed non-current-carrying metal
parts
500 VAC, 50/60 Hz for 1 min between current-carrying section and USB connector, and between current-
carrying terminals and non-current-carrying metal part of output connector
1 kV between power terminals
1.5 kV between current-carrying terminals and exposed non-current-carrying metal parts
±480 V between power terminals, ±600 V between input terminals
Square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise)
8 kV (malfunction), 15 kV (destruction)
10 to 55 Hz with 0.75-mm single amplitude each in 3 directions for 2 hours each
10 to 55 Hz with 0.5-mm single amplitude each in 3 directions for 10 minutes each
300 m/s2 3 times each in 6 directions
200 m/s2 3 times each in 6 directions
cULus (Listing): UL508/CSA C22.2 No. 14
(EMI)
EN61326
Emission Enclosure:
EN55011 Group1 Class A
(EMS)
EN61326
Immunity ESD:
EN61000-4-2: 4 kV contact discharge
8 kV air discharge
Immunity RF-interference:
EN61000-4-3: 10 V/m (Amplitude-modulated, 80 MHz to 1 GHz)
10 V/m (Pulse-modulated, 900 MHz ±5 MHz)
Immunity Conducted Disturbance EN61000-4-6: 10 V (0.15 to 80 MHz)
Immunity Burst:
EN61000-4-4: 2 kV for power-line
1 kV for I/O signal-line
Immunity Surge:
EN61000-4-5: 1 kV line to line (power line)
2 kV line to ground (power line)
Approx. 300 g (Cam Positioner main unit only)
Note: 1. Cam output precision, however, is 2° max. for Encoder with 256 resolution (P/R).
2. Although 32-output Models can have 10 steps set for any one output, there must be no more than 160 steps total set for all cam outputs.
3. The maximum is 1000 r/min when an E6CP-AG5C-C Encoder is connected.
4. ADV stands for Advance Angle Compensation.
4