EDE1144 Keypad Encoder IC
OVERVIEW OF OPERATION
Table One of the previous page illustrates the data that is output upon each keypress. The
following sequence is initiated upon each keypress, and is repeated if the key is held:
1. Keypress is detected
2. One scan cycle is performed
3. Parallel Outputs (D3..D0) are latched with the appropriate value
4. Data Valid signal is activated (pulled low)
5. Beeper (1KHz square wave) is activated for 45mS
6. Serial data is transmitted
This entire cycle takes 50mS (regardless of Baud rate selected). If a key is held longer than the
autorepeat delay of 660 mS, the cycle is repeated again at a rate of 5 times per second. The
following timing diagram illustrates the above sequence:
0ms
Keypress
Parallel_Outputs
1uS
Data_Valid_Output
Serial_Output
Beeper_Output
10ms
20ms
30ms
50mS
(Multiple transitions are due to contact bounce)
40ms
D3..D0 latched with appropriate value
50ms
45mS
(Square wave is not to scale)
Once a key is pressed, any additional closures (bounce) of that contact, or of any other contacts
are ignored for 50mS, during which several signals are output by the EDE1144. First, the parallel
outputs D0..D3 (Pins 6-9) are latched with the appropriate keypress value. One microsecond
later, the Data Valid Output (Pin 17) goes low, indicating that there is valid data on the parallel
output pins. Following this, the Beeper Output (Pin 18) pulse stream is generated for 45mS,
providing auditory confirmation to the keypad operator that a key has been pressed. Finally, the
RS-232 Output (Pin 1) transmits the keypress data at the Baud rate selected by the Baud rate input
select (Pin 2). After this, a variable (determined by Baud rate chosen) delay period is waited to
make the entire process to last precisely 50mS.
If a key is held longer that the autorepeat delay of 660mS, the outputs are cleared and this entire
process is repeated every 204mS until the key is released by the operator.