DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

HCPL-0723-300 查看數據表(PDF) - HP => Agilent Technologies

零件编号
产品描述 (功能)
生产厂家
HCPL-0723-300
HP
HP => Agilent Technologies HP
HCPL-0723-300 Datasheet PDF : 12 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
All Agilent data sheets report the
creepage and clearance inherent
to the optocoupler component
itself. These dimensions are
needed as a starting point for the
equipment designer when
determining the circuit insulation
requirements. However, once
mounted on a printed circuit
board, minimum creepage and
clearance requirements must be
met as specified for individual
equipment standards. For
creepage, the shortest distance
path along the surface of a
printed circuit board between the
solder fillets of the input and
output leads must be considered.
There are recommended
techniques such as grooves and
ribs, which may be used on a
printed circuit board to achieve
desired creepage and clearances.
Creepage and clearance distances
will also change depending on
factors such as pollution degree
and insulation level.
IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics (Option 060)
Description
Symbol
HCPL-7723
Option 060
Installation classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage 150 V rms
I-IV
for rated mains voltage 300 V rms
I-IV
for rated mains voltage 450 V rms
I-III
Climatic Classification
55/85/21
Pollution Degree (DIN VDE 0110/1.89)
2
Maximum Working Insulation Voltage
VIORM
630
Input to Output Test Voltage, Method b*
VPR
1181
VIORM x 1.875 = VPR, 100% Production Test with tm = 1 sec,
Partial Discharge < 5 pC
Input to Output Test Voltage, Method a*
VIORM x 1.5 = VPR, Type and Sample Test, tm = 60 sec,
Partial Discharge < 5 pC
VPR
945
Highest Allowable Overvoltage*
(Transient Overvoltage, tini = 10 sec)
VIOTM
6000
Safety Limiting Values (maximum values allowed in the
event of a failure, also see Thermal Derating curve,
Figure 11)
Case Temperature
Input Current
Output Power
Insulation Resistance at TS, VIO = 500 V
TS
175
IS,INPUT 230
PS,OUTPUT 600
RIO
109
HCPL-0723
Option 060 Units
I-IV
I-III
55/85/21
2
560
1050
V peak
V peak
840
V peak
4000
V peak
150
°C
150
mA
600
mW
109
*Refer to the front of the optocoupler section of the Isolation and Control Component Designer’s Catalog, under Product Safety Regulations section
IEC/EN/DIN EN 60747-5-2, for a detailed description.
Note: These optocouplers are suitable for “safe electrical isolation” only within the safety limit data. Maintenance of the safety data shall be
ensured by means of protective circuits.
Note: The surface mount classification is Class A in accordance with CECC 00802.