HA-2540
Electrical Specifications VSUPPLY = ±15V, RL = 1kΩ, CL < 10pF, Unless Otherwise Specified (Continued)
PARAMETER
TEMP
(oC)
HA-2540-2
MIN TYP MAX
HA-2540-5
MIN TYP MAX
HA-2540C-5
MIN TYP MAX
POWER REQUIREMENTS
Supply Current
Full
-
20
25
-
20
25
-
20
25
Power Supply Rejection Ratio (Note 9)
Full
60
70
-
60
70
-
60
70
-
NOTES:
3. RL = 1kΩ, VO = ±10V.
4. VCM = ±10V.
5. VO = 90mV.
6.
7.
8.
AV = 10.
Full power bandwidth guaranteed based on slew rate
Refer to Test Circuits section of the data sheet.
measurement
using:
FPBW
=
2-S---π-l-e--V-w---P---R-E----aA---t-K-e-- .
9. VSUPPLY = +5V, -15V and +15V, -5V.
10. Guaranteed range for output voltage is ±10V. Functional operation outside of this range is not guaranteed.
UNITS
mA
dB
Test Circuits and Waveforms
VIN
+-
VOUT
900
NOTES:
100
11. AV = +10.
12. CL ≤ 10pF.
FIGURE 1. LARGE AND SMALL SIGNAL RESPONSE TEST CIRCUIT
A
B
Vertical Scale: A = 0.5V/Div., B = 5.0V/Div.
Horizontal Scale: 50ns/Div.
Vertical Scale: Input = 10mV/Div.; Output = 50mV/Div.
Horizontal Scale: 20ns/Div.
LARGE SIGNAL RESPONSE
V+
0.001µF
INPUT 200Ω
1µF
-
+
0.001µF
500Ω
SETTLE
POINT
1µF
V-
2kΩ
5kΩ
OUTPUT
PROBE
MONITOR
SMALL SIGNAL RESPONSE
NOTES:
13. AV = -10.
14. Load Capacitance should be less than 10pF. Turn on time delay
typically 4ns.
15. It is recommended that resistors be carbon composition and the
feedback and summing network ratios be matched to 0.1%.
16. SETTLE POINT (Summing Node) capacitance should be less
than 10pF. For optimum settling time results, it is recommended
that the test circuit be constructed directly onto the device pins. A
Tektronix 568 Sampling Oscilloscope with S-3A sampling heads is
recommended as a settle point monitor.
FIGURE 2. SETTLING TIME TEST CIRCUIT
3