DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

HT16523 查看數據表(PDF) - Holtek Semiconductor

零件编号
产品描述 (功能)
生产厂家
HT16523
Holtek
Holtek Semiconductor Holtek
HT16523 Datasheet PDF : 23 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
HT16523
Number of Digits Set Command
Byte R/W Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0
1st W 1
0
1
*
* K2 K1 K0
*: Don’t care
The number of digits set command descriptions is are
described by the following:
• K2~K0: number of digit selections
• The number of display digits can be from 9 to 16
digits using the 3 selection bits.
• The relationship between setup data and the
displayed grid is shown in the table.
HEX
K2
K1
K0
Number of
Digits of Grid
Comment
Default state when power is
0 0 0 0 G1 to G16 applied or when the RST input is
at a low level.
1 0 0 1 G1 to G9
2 0 1 0 G1 to G10
3 0 1 1 G1 to G11
4 1 0 0 G1 to G12
5 1 0 1 G1 to G13
6 1 1 0 G1 to G14
7 1 1 1 G1 to G15
All Display Lights On/Off Set Command
Byte R/W Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0
1st W 1
1
0
*
D
S
H
L
*: Don’t care
The display ON/OFF set command descriptions are
described by the following:
• S bit: S=“1” is standby mode; S=“0” is normal
mode
• D bit: D=“1” is display ON; D=“0” is display OFF
• H bit: set all lights ON
• L bit: set all lights OFF
• When S bit = “1”, the internal oscillator stops and
all outputs are set to low and the general port is set
to high (P2 and P1 are all at high levels)
• When S bit = “1”, all registers will keep their
original value
• After being woken up, the device will set the S and
D bits to “0”
• The “All display lights ON” command is used
primarily for display testing
• The “All display lights OFF” command is primarily
used for display flashing
• The command bits, including D, H and L bits,
cannot control the general output port
• The relationship between the control bits and
display state of G1~G16, S1~S35 and AD1~AD2
pins is shown in the table.
DSHL
Driver Output Status
Comment
1 0 0 0 Normal display
Sets all segments and Sets all
1
0
0
1
segments and AD to Low.
All grids maintain scan
General ports active AD to Low
Sets all segments and AD to High
1 0 1 * All grids maintain scan
General ports active
Display off mode
Sets all segments and AD to Low (Default state when
0 0 * * Sets all grids to Low
power is applied or
General ports active
when the RST input
is at a low level.)
Sets all segments and AD to Low.
* 1 * * Sets all grids to Low.
Standby mode
Set General ports to high.
*: Don’t care
Wake-up Setting
The wake-up behavior is described by the following:
• The device is woken up when a CS low pulse is
asserted i.e. when a CS signal falling edge occurs.
• The D and S control bits described in the preceding
section will be set to “0” - display off mode
• The oscillator starts to oscillate after wake-up
• The VFD driver does not display until the host
MCU transmits commands to it.
Wake-up
CS
SCK
SI
TEST Command
Byte R/W Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0
1st W 1
1
1
0
0
0
0
0
The TEST command is described by the following:
• Only when the TEST pin is high is the TEST
command “E0H” is valid
• This command is used by HOLTEK for internal
testing.
Rev. 1.00
18
January 18, 2012

Share Link: 