DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

HT82K629A 查看數據表(PDF) - Holtek Semiconductor

零件编号
产品描述 (功能)
生产厂家
HT82K629A
Holtek
Holtek Semiconductor Holtek
HT82K629A Datasheet PDF : 23 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
HT82K629A
Functional Description
Command from the Host
The following table shows the commands that the host
may send and their hexadecimal values.
Command
Set/Reset Status Indicators
Echo
Invalid Command
Select Alternate Scan Codes
Invalid Command
Read ID
Set Typematic Rate/Delay
Enable
Default Disable
Set Default
Set All Keys - Typematic
Set All Keys - Make/Break
Set All Keys - Make
Set All Keys - Typematic/Make/Break
Hex Value
ED
EE
EF
F0
F1
F2
F3
F4
F5
F6
F7
F8
F9
FA
Set Key Type - Typematic
FB
Set Key Type - Make/Break
FC
Set Key Type - Make
FD
Resend
FE
Reset
FF
The commands may be sent to the HT82K629A at any
time and the HT82K629A will respond within 25ms ex-
cept when performing the internal diagnostics or execut-
ing a Reset command.
EDH - Set/Reset Status Indicators
Three status indicators on the keyboard-Num Lock,
Caps Lock, and Scroll Lock-are accessible by the host.
The HT82K629A activates or deactivates these indica-
tors when it receives a valid command-code sequence
from the system. The command sequence begins with
the command byte (hex ED). The HT82K629A responds
to the command byte with ACK, discontinues scanning,
assignments for this option byte are as follow:
Bit
Indicator
0
Scroll Lock Indicator
1
Num Lock Indicator
2
Caps Lock Indicator
3~7 Reserved (Must be 0)
If a bit for an indicator is set to 1, the indicator is turned
on. If a bit is set to 0, the indicator is turned off.
The HT82K629A responds to the option byte with ACK,
sets the indicators and if the HT82K629A was previously
enabled, continues scanning. The status of the indica-
tors will reflect the bits in the option byte and can be acti-
vated or deactivated in any combination. If another
command is received in place of the option byte, execu-
tion of the Set/Reset Mode Indicators command is
stopped, with no change to the indicator status, and the
new command is processed.
Immediately after power-on, the lights default to the off
state. If the Set Default and Default Disable commands
are received, the lamps remain in the state they were in
before the command was received.
EEH - Echo
Echo is a diagnostic aid. When the HT82K629A re-
ceives this command, it issues a hex EE response and if
the HT82K629A was previously enabled, continues
scanning.
EFH and F1H - Invalid Command
EFH and F1H are invalid commands and are not sup-
ported. If HT82K629A receives one of these and sends
it, the HT82K629A will not acknowledge the command,
but returns a Resend command and continues in its pre-
vious scanning state.
F0H - Select Alternate Scan Codes
This command instructs the HT82K629A to select one of
the two sets of scan codes. The HT82K629A acknowl-
edges receipt of this command with ACK, clears both
the output buffer and the typematic key. The host then
sends the option byte and the keyboard responds with
another ACK. An option byte value of hex 01 selects
scan code set 1, hex 02 selects set 2.
An option byte value of hex 00 causes the HT82K629A
to acknowledge with ACK and sends a byte telling the
host which scan code set is currently in use.
After establishing the new scan code set, the
HT82K629A returns to the scanning state it was in be-
fore receiving the Select Alternate Scan Codes com-
mand.
F2H - Read ID
This command requests identification information from
the HT82K629A. The HT82K629A responds with ACK,
discontinues scanning and sends the two keyboard ID
bytes hex 83h and ABh. After the output of the second
ID byte, the HT82K629A resumes scanning.
Rev. 1.30
4
April 16, 2004

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]