█ Reliability Test Item And Condition
IR958-8P
The reliability of products shall be satisfied with items listed below.
Confidence level:90%
LTPD:10%
NO.
Item
Test Conditions
1 Solder Heat
TEMP.:260℃±5℃
2 Temperature Cycle H : +85℃ 30mins
L : -55℃
5mins
30mins
3 Thermal Shock H :+100℃ 5mins
L :-10℃
10secs
5mins
4 High Temperature TEMP.:+100℃
Storage
5 Low Temperature TEMP.:-55℃
Storage
Test
Hours/
Cycles
10 secs
50 Cycles
50 Cycles
1000 hrs
1000 hrs
Sample
Sizes
Failure
Judgment
Criteria
22pcs
22pcs
IR≧U×2
Ic(ON)≦L×0.8
VF≧U×1.2
22pcs
U:Upper
Specification
22pcs Limit
L:Lower
22pcs Specification
Limit
Ac/Re
0/1
0/1
0/1
0/1
0/1
6 DC Operating Life IF=20mA
1000 hrs 22pcs
0/1
7 High Temperature/ 85℃ / 85% R.H
1000 hrs 22pcs
0/1
High Humidity
EVERLIGHT ELECTRONICS CO., LTD.
Office: No 25, Lane 76, Sec 3, Chung Yang Rd,
Tucheng, Taipei 236, Taiwan, R.O.C
Tel: 886-2-2267-2000, 2267-9936
Fax: 886-2267-6244, 2267-6189, 2267-6306
http:\\www.everlight.com
Everlight Electronics Co., Ltd.
http:\\www.everlight.com
Device No:DIR-958-142
Rev 2
Page:7 of 6