ISSI ®
WRITE STATUS REGISTER (WRSR)
This instruction lets the user choose a Block Protection
setting. The values of the other data bits incorporated
into WRSR can be 0 or 1, and are not stored in the
Status Register. WRSR will be ignored unless both the
following are true: a) WEN = 1, due to a prior WREN
instruction; and b) Hardware Write Protection is not
enabled. (See Table 4 for details). Except for the RDY
status, the values in the Status Register remain un-
changed until the moment when the write cycle is
complete and the register is updated. Once successfully
completed, WEN is reset for complete chip write protec-
tion. (See Figure 5 for timing).
READ DATA (READ)
This instruction begins with the op-code and the 8-bit
address, and causes the selected data byte to be
shifted out on SO. Following this first data byte, addi-
tional sequential bytes are output. If the data byte in the
highest address is output, the address rolls-over to the
lowest address in the array, and the output could loop
indefinitely. At any time, a rising CS signal completes
the operation. (See Figure 6 for timing).
WRITE DATA (WRITE)
The WRITE instruction begins with the op-code, the 8-bit
address of the first byte to be modified, and the first data
byte. Additional data bytes may be written sequentially
to the array after the first byte. Each WRITE instruction
can affect the contents of a 16 byte page, but no more.
The page begins at address XXXX 0000, and ends with
XXXX 1111. If the last byte of the page is input, the
address rolls over to the beginning of the same page.
More than 16 data bytes can be input during the same
instruction, but upon a completed write cycle, a page
would only contain the last 16 bytes.
The region of the array defined within Block Protection
cannot be modified as long as that block configuration is
selected. The region of the array outside the Block
Protection can only be modified if Write Enable (WEN) is
set to 1. Therefore, it may be necessary that a WREN
instruction occur prior to WRITE. In addition, if Hardware
Write Protection is enabled, the memory array cannot be
modified. Once Write is successfully completed, WEN
is reset for complete chip write protection. (See Figure 7
for timing).
Table 5. Address Key
Name
AN
Don't
Care Bits
IS25C02
A7-A0
A8
IS25C04
A8-A0
-
Table 4. Write Protection
WP Hardware Write
Protection
0
Enabled
1
Not Enabled
1
Not Enabled
Note: X = Don't care bit.
WEN Inside Block Outside Block
X
Read-only
Read-only
0
Read-only
Read-only
1
Read-only
Unprotected
Status Register
Read-only
Read-only
Unprotected
6