LIMITING VALUES
In accordance with the Absolute Maximum Rating System (IEC 134).
SYMBOL
PARAMETER
Icont
continuous sensor current
Tamb
ambient operating temperature
CONDITIONS
in free air; Tamb = 25 °C
in free air; Tamb = 150 °C
MIN.
55
MAX.
10
2
+150
UNIT
mA
mA
°C
CHARACTERISTICS
Tamb = 25 °C, in liquid, unless otherwise specified.
SYMBOL
PARAMETER
CONDITIONS
MIN.
R25
TC
R100/R25
R55/R25
τ
sensor resistance
KTY81-110
KTY81-120
KTY81-121
KTY81-122
KTY81-150
KTY81-151
KTY81-152
temperature coefficient
resistance ratio
resistance ratio
thermal time constant; note 1
rated temperature range
Icont = 1 mA
990
980
980
1 000
950
950
1 000
Tamb = 100 °C and 25 °C 1.676
Tamb = 55 °C and 25 °C 0.480
in still air
in still liquid; note 2
in flowing liquid; note 2
55
TYP.
0.79
1.696
0.490
30
5
3
MAX.
1 010
1 020
1 000
1 020
1 050
1 000
1 050
1.716
0.500
+150
UNIT
%/K
s
s
s
°C
Notes
1. The thermal time constant is the time taken for the sensor to reach 63.2% of the total temperature difference. For
example, if a sensor with a temperature of 25 °C is moved to an environment with an ambient temperature of 100 °C,
the time for the sensor to reach a temperature of 47.4 °C is the thermal time constant.
2. Inert liquid, e.g. FC43 manufactured by the 3M company.