APPLICATIO S I FOR ATIO
cause the second form of clock feedthrough described
above, when averaged, dominate the DC input bias current
of the op amp below 70°C.
At temperatures above 70°C, the leakage of the ESD
protection diodes on the inputs increases the input bias
currents of both inputs in the positive direction, while the
current caused by the charge injection stays relatively
constant. At elevated temperatures (above 70°C) the
leakage current begins to dominate and both the negative
and positive pins’ input bias currents are in the positive
direction (into the pins).
Extended Common Mode Range
The LTC2054/LTC2055 input stage is designed to allow
nearly rail-to-rail input common mode signals. In addition,
signals that extend beyond the allowed input common
mode range do not cause output phase inversion.
LTC2054/LTC2055
Voltage Follower with Input Exceeding
the Common Mode Range
2.5V
1k
±3.75VP
SINE WAVE
–
LTC2054/55
+
–2.5V
OUTPUT
100k
2054 TA09
LTC2054/LTC2055
Extended Common Mode Range
0V
0V
AV = 1
500µs/DIV
RL = 100k
VS = ±2.5V
VIN = 500Hz 7.5VP-P
2054 G19
TYPICAL APPLICATIO S
Simple Differential Bridge Amplifier
5V
LT1790-2.5
10kΩ
BRIDGE
5V
0.1µF
1µF
499k
4– 5
LTC2054HV 1
3+
2
0.1µF 499k
– 5V
AV = 100
20545 TA02
sn20545 20545fas