DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

LTC2619I 查看數據表(PDF) - Linear Technology

零件编号
产品描述 (功能)
生产厂家
LTC2619I Datasheet PDF : 22 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
LTC2609/LTC2619/LTC2629
TIMING CHARACTERISTICS The l denotes the specifications which apply over the full operating temperature
range, otherwise specifications are at TA = 25°C. (See Figure 1) (Notes 8, 9)
SYMBOL PARAMETER
CONDITIONS
MIN
TYP
MAX
UNITS
VCC = 2.7V to 5.5V
fSCL
SCL Clock Frequency
tHD(STA) Hold Time (Repeated) Start Condition
tLOW
Low Period of the SCL Clock Pin
tHIGH
High Period of the SCL Clock Pin
tSU(STA) Set-Up Time for a Repeated Start Condition
tHD(DAT) Data Hold Time
tSU(DAT) Data Set-Up Time
tr
Rise Time of Both SDA and SCL Signals
tf
Fall Time of Both SDA and SCL Signals
tSU(STO) Set-Up Time for Stop Condition
tBUF
Bus Free Time Between a Stop and Start Condition
t1
Falling Edge of 9th Clock of the 3rd Input Byte to
LDAC High or Low Transition
t2
LDAC Low Pulse Width
(Note 7)
(Note 7)
l
0
l 0.6
l 1.3
l 0.6
l 0.6
l
0
l 100
l 20 + 0.1CB
l 20 + 0.1CB
l 0.6
l 1.3
l 400
l
20
400
kHz
μs
μs
μs
μs
0.9
μs
ns
300
ns
300
ns
μs
μs
ns
ns
Note 1: Stresses beyond those listed under Absolute Maximum Ratings
may cause permanent damage to the device. Exposure to any Absolute
Maximum Rating condition for extended periods may affect device
reliability and lifetime.
Note 2: Linearity and monotonicity are defined from code kL to code
2N – 1, where N is the resolution and kL is given by kL = 0.016(2N/VREF),
rounded to the nearest whole code. For VREF = 4.096V and N = 16, kL =
256 and linearity is defined from code 256 to code 65,535.
Note 3: SDA, SCL at 0V or VCC, CA0, CA1 and CA2 floating.
Note 4: Inferred from measurement at code kL (see Note 2) and at full-Scale.
Note 5: VCC = 5V, VREF = 4.096V. DAC is stepped 1/4 scale to 3/4 scale and
3/4 scale to 1/4 scale. Load is 2k in parallel with 200pF to GND.
Note 6: VCC = 5V, VREF = 4.096V. DAC is stepped ±1LSB between half scale
and half scale – 1. Load is 2k in parallel with 200pF to GND.
Note 7: CB = capacitance of one bus line in pF.
Note 8: All values refer to VIH(MIN) and VIL(MAX) levels.
Note 9: These specifications apply to LTC2609/LTC2609-1,
LTC2619/LTC2619-1, LTC2629/LTC2629-1.
Note 10: DC crosstalk is measured with VCC = 5V, REFA = REFB = REFC
= REFD = 4.096V, with the measured DAC at mid-scale, unless otherwise
noted.
Note 11: RL = 2kΩ to GND or VCC.