DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

LTC3776EUF 查看數據表(PDF) - Linear Technology

零件编号
产品描述 (功能)
生产厂家
LTC3776EUF Datasheet PDF : 28 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
U
OPERATIO (Refer to Functional Diagram)
phase detector adjusts the voltage on the PLLLPF pin to
align the turn-on of controller 1’s external P-channel
MOSFET to the rising edge of the synchronizing signal.
Thus, the turn-on of controller 2’s external P-channel
MOSFET is 180 degrees out of phase with the rising edge
of the external clock source.
The typical capture range of the LTC3776’s phase-locked
loop is from approximately 200kHz to 1MHz, with a
guarantee over all process variations and temperature to
be between 250kHz and 850kHz. In other words, the
LTC3776’s PLL is guaranteed to lock to an external clock
source whose frequency is between 250kHz and 850kHz.
Alternatively, the SYNC/SSEN pin may be tied to VIN to
–10
RBW = 3kHz
–20
–30
–40
–50
–60
–70
–80
–90
–100
–110
0
6
12
18
24
30
FREQUENCY (MHz)
37361 F01a
Figure 1a. Output Noise Spectrum of Conventional Buck
Switching Converter (LTC3776 with Spread Spectrum
Disabled) Showing Fundamental and Harmonic Frequencies
–10
RBW = 1kHz
–20
–30
–40
–50
–60
–70
–80
–90
–100
–110
0
6
12
18
FREQUENCY (MHz)
24
30
37361 F01c
Figure 1c. Output Noise Spectrum of the LTC3776 Spread
Spectrum Buck Switching Converter. Note the Reduction in
Fundamental and Harmonic Peak Spectral Amplitude
Compared to Figure 1a.
LTC3776
enable spread spectrum operation (see Spread Spectrum
Operation section).
Spread Spectrum Operation
Switching regulators can be particularly troublesome in
applications where electromagnetic interference (EMI) is
a concern. Switching regulators operate on a cycle-by-
cycle basis to transfer power to an output. In most cases,
the frequency of operation is either fixed or is a constant
based on the output load. This method of conversion
creates large components of noise at the frequency of
operation (fundamental) and multiples of the operating
frequency (harmonics). Figures 1a and 1b depict the
–10
RBW = 30Hz
–20
–30
–40
–50
–60
–70
–80
–90
–100
–110
410
450 490 530 570 610
FREQUENCY (kHz)
37361 F01b
Figure 1b. Zoom-In of Fundamental Frequency of Conventional
Buck Switching Converter
–10
RBW = 30Hz
–20
–30
–40
–50
–60
–70
–80
–90
–100
–110
410
450 490 530 570 610
FREQUENCY (kHz)
37361 F01d
Figure 1d. Zoom-In of Fundamental Frequency of the
LTC3776 Spread Spectrum Switching Converter. Note the
>20dB Reduction in Peak Amplitude and Spreading of the
Frequency Spectrum (Between Approximately 450kHz and
580kHz) Compared to Figure 1b.
3776f