M40Z300, M40Z300W
DC AND AC PARAMETERS
This section summarizes the operating and mea-
surement conditions, as well as the DC and AC
characteristics of the device. The parameters in
the following DC and AC Characteristic tables are
derived from tests performed under the Measure-
ment Conditions listed in the relevant tables. De-
signers should check that the operating conditions
in their projects match the measurement condi-
tions when using the quoted parameters.
Table 4. DC and AC Measurement Conditions
Parameter
VCC Supply Voltage
Ambient Operating Temperature
Grade 1
Grade 6
Load Capacitance (CL)
Input Rise and Fall Times
Input Pulse Voltages
Input and Output Timing Ref. Voltages
Note: Output High Z is defined as the point where data is no longer driven.
M40Z300
4.5 to 5.5V
0 to 70°C
–40 to 85°C
100pF
≤ 5ns
0 to 3V
1.5V
M40Z300W
2.7 to 3.6V
0 to 70°C
–40 to 85°C
50pF
≤ 5ns
0 to 3V
1.5V
Figure 10. AC Testing Load Circuit
DEVICE
UNDER
TEST
333Ω
CL = 100pF
or 50pF
1.73V
CL includes JIG capacitance
AI02393
Note: 50pF for M40Z300W.
Table 5. Capacitance
Symbol
Parameter(1,2)
Min
CIN Input Capacitance
COUT(3) Input/Output Capacitance
Note: 1. Sampled only, not 100% tested.
2. At 25°C, f = 1MHz.
3. Outputs deselected.
Max
8
10
Unit
pF
pF
11/21