DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

M65665 查看數據表(PDF) - MITSUBISHI ELECTRIC

零件编号
产品描述 (功能)
生产厂家
M65665
Mitsubishi
MITSUBISHI ELECTRIC  Mitsubishi
M65665 Datasheet PDF : 15 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
MITSUBISHI DIGITAL TV ICs
M65665SP/FP
PICTURE-IN-PICTURE SIGNAL PROCESSING
The relation of input signal 32-pin (Main-HD) and 33-pin (Main-VD) is shown below
32-pin
input
(Main-HD)
33-pin input
(Main-VD)
-10usec
[Even to Odd]
33-pin input
(Main-VD)
[Odd to Even]
0
+10usec
+21.75usec
prohibition time of
changing 33-pin signal
+41.75usec
+53.5usec
20us
20us
20us
20us
20us
20us
VD input
4H
1H
end of vertical equalization pulse
37.5us
20us
20us
20us
20us
20us
20us
VD input
Driv ing Method and Operating Specif ication f or Serial Interf ace Data
(1) Serial data transmission completion and start
A low-to-high transition of the DATA (serial data) line while the CLK (serial clock) is high, that completes the serial transmission and makes the
bus free.
A high-to-low transition of the DATA line while the CLK is high, that starts the serial transmission and waits for the following CLK and DATA
inputs.
(2) Serial data transmission
The data are transmitted in the most significant bit (MSB) first by one-byte unit on the DATA line successively. One-byte data transmission is
completed by 9 clock cycles, the former 8 cycles are for address/data and the latter one is for acknowledge detection. (In reading state, ACK is 'H'
under these two conditions ; 1) the coincidence of two address data for the address data transmission, 2) the completion of 8-bit setting data
transfer. In writing state, ACK is 'H' with the address coincidence and ACK is 'L' for detecting acknowledge input from the master (micro
processor) after sending 8-bit setting data.)
For address/data transmission, DATA must change while CLK is 'L'. (The data change while CLK is 'H' or the simultaneous change of CLK and
DATA, that will be a false operation because of undistinguished condition from the completion/start of serial data transfer).
After the beginning of serial data transmission, the total number of data bytes that can be transferred are not limited.
(3) The byte format of data transmission (The sequence of data transmission)
a. The byte format during data setting to M65665FP are shown as follows.
In right after the forming of serial data transmitting state, the slave address 24h (00100100b) is transferred. Afterwards, the internal register
address (1 byte) and setting data (by 1 byte unit) are transferred successively. Several bytes of setting data can be handled in the one
transmission. In this operation, the setting data are written into the address register whose address is increased one in initially transferred internal
register address.
b. The byte format during data reading from M65665FP are shown as follows.
Before data reading from M65665FP, whose internal address need to be set by the data reading/transmitting. After the data reading/transmitting,
the operation of "serial data transmission completion and start" (described in (1)) is necessary. Continuously, the slave address 25h (00100101b)
is sent, and then the inverted read out data are available on ACK. Several bytes of writing data can be handled in the one transmission, too. In this
operation, the setting data also are written into the address register whose address is increased one in initially transferred internal register address.
MITSUBISHI
10
ELECTRIC

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]