DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

LT1341CSW 查看數據表(PDF) - Linear Technology

零件编号
产品描述 (功能)
生产厂家
LT1341CSW Datasheet PDF : 8 Pages
1 2 3 4 5 6 7 8
LT1341
ELECTRICAL CHARACTERISTICS (Note 2)
PARAMETER
CONDITIONS
MIN TYP MAX
UNITS
Any Driver
Output Voltage Swing
Load = 3k to GND
Positive
q
5
7.3
V
Negative
q
– 6.5 – 5
V
Logic Input Voltage Level
Logic Input Current
Output Short-Circuit Current
Output Leakage Current
Data Rate (Note 7)
Slew Rate
Propagation Delay
Any Receiver
Input Low Level (VOUT = High)
Input High Level (VOUT = Low)
0.8V VIN 2V
VOUT = 0V
Shutdown VOUT = ±30V (Note 4)
RL = 3k, CL = 2500pF
RL = 3k, CL = 1000pF
RL = 3k, CL = 51pF
RL = 3k, CL = 2500pF
Output Transition tHL High to Low (Note 5)
Output Transition tLH Low to High
q
q
2
1.4
0.8
1.4
q
5
20
±9
±17
q
10
100
120
250
15
30
4
6
0.6
1.3
0.5
1.3
V
V
µA
mA
µA
kBaud
kBaud
V/ µs
V/ µs
µs
µs
Input Voltage Thresholds
Hysteresis
Input Low Threshold (VOUT = High)
Input High Threshold (VOUT = Low)
0.8
1.3
V
1.7
2.4
V
q 0.1
0.4
1.0
V
Input Resistance
Output Leakage Current
Receivers 1 Through 4
Shutdown (Note 4) 0 VOUT VCC
3
5
7
k
q
1
10
µA
Output Voltage
Output Short-Circuit Current
Propagation Delay
Receiver 5 (Low-IQ RX)
Output Voltage
Output Short-Circuit Current
Propagation Delay
Output Low, IOUT = – 1.6mA
Output High, IOUT = 160µA (VCC = 5V)
Sinking Current, VOUT = VCC
Sourcing Current, VOUT = 0V
Output Transition tHL High to Low (Note 6)
Output Transition tLH Low to High
Output Low, IOUT = – 500µA
Output High, IOUT = 160µA (VCC = 5V)
Sinking Current, VOUT = VCC
Sourcing Current, VOUT = 0V
Output Transition tHL High to Low (Note 6)
Output Transition tLH Low to High
q
0.2
0.4
V
q 3.5
4.2
V
– 20 – 10
mA
10
20
mA
250
600
ns
350
600
ns
q
0.2
0.4
V
q 3.5
4.2
V
–4
–2
mA
2
4
mA
1
3
µs
1
3
µs
The q denotes specifications which apply over the full operating
temperature range (0°C TA 70°C for commercial grade).
Note 1: Absolute Maximum Ratings are those values beyond which the life
of the device may be impaired.
Note 2: Testing done at VCC = 5V and VON/OFF = 3V.
Note 3: Supply current is measured as the average over several charge
pump cycles. C + = C = 0.1µF, C1 = C2 = 0.2µF. All outputs are open with
all driver inputs tied high.
Note 4: Supply current and leakage measurements in shutdown are
performed with VON/OFF 0.1V. Supply current measurements using driver
disable are performed with VDRIVER DISABLE 3V.
Note 5: For driver delay measurements, RL = 3k and CL = 51pF. Trigger
points are set between the driver’s input logic threshold and the output
transition to the zero crossing (tHL = 1.4V to 0V and tLH = 1.4V to 0V).
Note 6: For receiver delay measurements, CL = 51pF. Trigger points are
set between the receiver’s input logic threshold and the output transition
to standard TTL/CMOS logic threshold (tHL = 1.3V to 2.4V and tLH = 1.7V
to 0.8V).
Note 7: Data rate operation guaranteed by slew rate, short-circuit current
and propagation delay tests.
3

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]