DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MAS9079 查看數據表(PDF) - Micro Analog systems

零件编号
产品描述 (功能)
生产厂家
MAS9079
MAS
Micro Analog systems MAS
MAS9079 Datasheet PDF : 9 Pages
1 2 3 4 5 6 7 8 9
DA9079.003
19 May, 2005
FREQUENCY SELECTION
The frequency selection and power down control is
accomplished via two digital control pins PDN1 and
PDN2. The control logic is presented in table 1.
Table 1 Frequency selection and power down control
PDN1
PDN2 RFI2 Switch RFI3 Switch
High
High
Low
High
Low
High
Open
Open
Closed
Open
Open
Open
Selected Crystal
Output
-
QO1
QO2
Low
Low
Closed
Closed
QO3
Description
Power down
Frequency 1
Frequency 2, RFI2 capacitor
connected in parallel with antenna
Frequency 3, RFI2 and RFI3
capacitors connected in parallel
with antenna
The internal antenna tuning capacitor switches
(RFI2, RFI3) and crystal filter output switches
(QO1, QO2, QO3) are controlled according table 1.
See switches in block diagram on page 1.
If frequency 1 is selected the RFI2 and RFI3
switches are open and only crystal output QO1 is
active. Antenna frequency is determined by
antenna inductor LANT (see Typical Application on
page 5), antenna capacitor CANT1 and parasitic
capacitances related to antenna inputs RFI1, RFI2
and RFI3 (see Antenna Tuning Considerations
below). Frequency 1 is the highest frequency of the
three selected frequencies.
If frequency 2 is selected then RFI2 switch is closed
to connect CANT2 in parallel with ferrite antenna and
tune it to frequency 2. Then only crystal output QO2
is active. Frequency 2 is the medium frequency of
the three selected frequencies.
If frequency 3 is selected both RFI2 and RFI3
switches are closed to connect both CANT2 and
CANT3 capacitors in parallel with ferrite antenna and
tune it to frequency 3. Then only crystal QO3 is
active. Frequency 3 is the lowest frequency of the
three selected frequencies.
It is recommended to switch the device to power
down for 50ms before switching to another
frequency. This guarantees fast startup in switching
to another frequency. The 50ms power down period
is used to discharge AGC capacitor and to initialize
fast startup conditions.
3 (9)

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]