GaAs SP3T 2.7 V CDMA-GPS Switch
DC - 2.5 GHz
MASWSS0060
V4
Electrical Specifications: TA = 25°C, Z0 = 50 Ω1
Parameter
Test Conditions
Insertion Loss2
(All Paths)
1.0 GHz
1.5 GHz
2.0 GHz
Isolation
DC - 1.0 GHz
1.0 - 2.0 GHz
2.0 - 2.5 GHz
Return Loss
(All RF ports)
DC - 2.5 GHz
IP3
Two Tone, +22 dBm/tone, 1 MHz Spacing, 820 MHz
Two Tone, +22 dBm/tone, 1 MHz Spacing, 1880 MHz
Cross Modulation
For Cell Band: Two-tone signal input:
Tx1 = +22 dBm @ 820 MHz, Tx2 = +22 dBm @ 821 MHz,
RX interfere = -23 dBm @ 869 MHz
For PCS Band: Two-tone signal input:
Tx1 = +18 dBm @ 1880 MHz, Tx2 = +18 dBm @ 1881 MHz,
RX interfere = -23 dBm @ 1960 MHz
P.1dB
Vc = 0 V/2.7 V, 1 GHz
Trise, Tfall
10% to 90% RF, 90% to 10% RF, 900 MHz
Ton, Toff
50% control to 90% RF, and 50% control to 10% RF, 900 MHz
Transients
In Band
Control Current
Vc = 0 V/2.7 V
Units
dB
dB
dB
dB
dB
dB
dB
dBm
dBm
dBm
dBm
dBm
µS
µS
mV
µA
Min.
—
—
—
23
18
16
—
—
—
—
—
—
—
—
—
—
Typ.
0.55
0.60
0.70
27
21
20
20
62
61
-101
-102
36
0.06
0.09
70
—
Max.
0.70
0.75
0.90
—
—
—
—
—
—
—
—
—
—
—
—
30
1. External DC blocking capacitors are required on all RF ports.
2. Insertion Loss can be optimized by varying the DC blocking capacitor value, e.g. 1000 pF for 100 MHz - 500 MHz, 100 pF for 0.5 - 2.5 GHz.
Absolute Maximum Ratings 3,4
Parameter
Absolute Maximum
Input Power
(0.5 - 2.5 GHz, 2.7 V Control)
+36 dBm
Control Voltage
Operating Temperature
Storage Temperature
±8.5 volts
-40°C to +85°C
-65°C to +150°C
3. Exceeding any one or combination of these limits may cause
permanent damage to this device.
4. M/A-COM does not recommend sustained operation near
these survivability limits.
Truth Table 5,6
V1 V2 V3 ANT-RF1 ANT-RF2 ANT-RF3
1
0
0
On
Off
Off
0
1
0
Off
On
Off
0
0
1
Off
Off
On
5. Differential voltage, V (state 1) -V (state 0) must be 2.6 V
minimum and must not exceed 8.5 V.
6. 0 = -5 V to 2.4 V, 1 = -2.4 V to 5 V.
2
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.