MASWSS0169
GaAs High Isolation Switch
DC - 3.0 GHz
Rev. V3
Electrical Specifications: TA = 25°C, VC = 0 / 3 V, Z0 = 50Ω
Parameter
Test Conditions
Units
Min
Typ
Max
Insertion Loss
500 MHz - 1.0 GHz
1.0 - 2.0 GHz
2.0 - 3.0 GHz
dB
—
0.55
0.65
dB
—
0.65
—
dB
—
0.80
—
Isolation
500 MHz - 2.0 GHz
2.0 - 3.0 GHz
dB
45
47
—
dB
—
33
—
VSWR
0.25 - 3.0 GHz
Ratio
—
1.2:1
—
P1dB
500 MHz - 2.0 GHz, VC = 3 V
dBm
—
20
—
P1dB
500 MHz - 2.0 GHz, VC = 5 V
dBm
—
28
—
IP2
2 Tone, 900 MHz, 5 MHz Spacing, VC = 3 V
dBm
—
85
—
IP3
2 Tone, 900 MHz, 5 MHz Spacing, VC = 3 V
dBm
—
50
—
Ton, Toff
50% Control to 90% RF, 50% Control to 10% RF
ns
—
20
—
Trise, Tfall
10% to 90% RF, 90% to 10% RF
ns
—
10
—
Transients
In-band
mV
—
15
—
Control Current
|VC| = 3.0 V
µA
—
5
20
Lead-Free MSOP-10†
† Reference Application Note M538 for lead-free solder reflow recommendations.
Meets JEDEC moisture sensitivity level 1 requirements.
Plating is 100% matte tin over copper.
2
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support